经桡动脉TACE中锥形束CT采集的简便化:旋转臂板的应用
该回顾性研究纳入2015年11月至2016年3月连续20例经桡动脉TACE(17例患者),使用旋转臂板在CBCT采集时重新定位入路手臂,40次重新定位全部成功,无导管或鞘管脱位,无微导管尖端位置改变,无入路相关并发症。作者认为旋转臂板是经桡动脉TACE中实现CBCT采集的有用辅助工具。
要点
- 经桡动脉TACE中,旋转臂板可在CBCT采集时重新定位入路手臂,40次操作全部成功。
- 使用旋转臂板重新定位手臂后,未发生导管或鞘管脱位,也未检测到微导管尖端位置改变。
- 全部患者止血成功,无入路相关并发症。
核心结论
- 旋转臂板是经桡动脉TACE中实现CBCT采集的有用辅助工具。
研究设计与样本
- 回顾性研究,纳入2015年11月至2016年3月连续经桡动脉TACE病例,共20例次(17例患者,男13例、女4例,平均年龄69.5岁,范围48-82岁),使用旋转臂板辅助CBCT采集。
关键影像表现/征象
- 使用旋转臂板进行手臂重新定位以完成CBCT采集共40次,成功率为100%。
- 手臂移动未导致导管或鞘管脱位。
- 手臂重新定位后未检测到微导管尖端位置改变。
临床应用与阅片要点
- 作者认为旋转臂板是经桡动脉TACE中实现CBCT采集的有用辅助工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Transradial access for peripheral intervention often requires certain modification from its coronary counterparts. One of the challenges during transradial transarterial chemoembolization (TACE) is the need for the access arm to be repositioned during cone-beam CT (CBCT) acquisition to allow for C-arm rotation. We recently introduced a swivel arm board to allow seamless repositioning of the access arm during and after CBCT acquisition. The purpose of this study is to detail the technique and feasibility of this useful adjunct to transradial TACE.
METHODS: We performed a retrospective study of consecutive cases of transradial TACE between November 2015 and March 2016, which represented the period where we introduced the swivel arm board to our transradial procedure. A total of 20 transradial TACE using the swivel arm board was performed in 17 patients. There were 13 males and 4 females. The mean age was 69.5 years old (range 48-82 years). Indications for TACE included hepatocellular carcinoma (n = 14) and metastatic liver disease (n = 3).
RESULTS: Transradial TACE was successful in all cases. A total of 40 successful arm repositioning using the swivel arm board for CBCT acquisitions were performed (100% success rate). There was no catheter or sheath dislodgement associated with the arm movements. No change in the microcatheter tip position was detected as a result of the arm repositioning. Hemostasis was successfully achieved in all the patients. There was no access related complication.
CONCLUSION: The swivel arm board is a useful adjunct to enable CBCT acquisition during transradial TACE. Advances in knowledge: Transradial TACE is a novel technique, and adaptation to allow for CBCT acquisition is currently challenging. This manuscript illustrates how to overcome the positioning difficulties with the use of the swivel arm board.
引用
- Pua U, Teo CC, U PT, et al. Cone-beam CT acquisition during transradial TACE made easy; use of the swivel arm board. Br J Radiol. 2017. PMID: 28937273. doi:10.1259/bjr.20170248
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。