文献速递心血管外周血管CT

冠状动脉粥样硬化中的暗场成像

Dark-field imaging in coronary atherosclerosis.
PubMed 文献 · Eur J Radiol · 2017-07-24

研究采用X射线管、光栅干涉仪和探测器对15个冠状动脉标本同步采集暗场、衰减和相位对比断层数据,以组织病理学为参考标准。结果显示,暗场高信号且衰减/相位无钙化证据的10/10横断面均存在微钙化,暗场对微钙化高度敏感,可能为斑块不稳定性评估提供补充信息。

要点

  • 暗场高信号而衰减/相位无钙化证据的横断面均存在微钙化。
  • 暗场成像对冠状动脉斑块微钙化高度敏感。
  • 暗场可能为斑块不稳定性评估提供补充信息。

核心结论

  • 暗场成像对冠状动脉粥样硬化斑块中的微钙化高度敏感,可能为斑块不稳定性评估提供补充信息。

研究设计与样本

  • 实验性研究,15个冠状动脉标本,采用X射线管(40kV)、光栅干涉仪和探测器同步采集暗场、衰减和相位对比断层数据,以组织病理学为参考标准,并进行模拟。

关键影像表现/征象

  • 暗场高信号而衰减或相位对比无钙化证据的横断面均存在微钙化。
  • 三种模态均呈高信号的阳性对照横断面均显示大钙化。
  • 无高信号的阴性对照未检测到钙化。

诊断标准与关键数值

  • 暗场高信号且衰减或相位对比无钙化证据的10/10(100%)横断面存在微钙化。
  • 三种模态均呈高信号的10/10(100%)横断面显示大钙化。
  • 模拟显示微钙化产生的暗场信号显著高于衰减信号。

临床应用与阅片要点

  • 暗场成像对微钙化高度敏感,可能为斑块不稳定性评估提供补充信息。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Dark-field imaging based on small angle X-ray scattering has been shown to be highly sensitive for microcalcifications, e.g. in breast tissue. We hypothesized (i) that high signal areas in dark-field imaging of atherosclerotic plaque are associated with microcalcifications and (ii) that dark-field imaging is more sensitive for microcalcifications than attenuation-based imaging.

METHODS: Fifteen coronary artery specimens were examined at an experimental set-up consisting of X-ray tube (40kV), grating-interferometer and detector. Tomographic dark-field-, attenuation-, and phase-contrast data were simultaneously acquired. Histopathology served as standard of reference. To explore the potential of dark field imaging in a full-body CT system, simulations were carried out with spherical calcifications of different sizes to simulate small and intermediate microcalcifications.

RESULTS: Microcalcifications were present in 10/10 (100%) cross-sections with high dark-field signal and without evidence of calcifications in attenuation- or phase contrast. In positive controls with high signal areas in all three modalities, 10/10 (100%) cross-sections showed macrocalcifications. In negative controls without high signal areas, no calcifications were detected. Simulations showed that the microcalcifications generate substantially higher dark-field than attenuation signal.

CONCLUSIONS: Dark-field imaging is highly sensitive for microcalcifications in coronary atherosclerotic plaque and might provide complementary information in the assessment of plaque instability.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Hetterich H, Webber N, Willner M, et al. Dark-field imaging in coronary atherosclerosis. Eur J Radiol. 2017. PMID: 28941758. doi:10.1016/j.ejrad.2017.07.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。