计算机辅助CT图像特征对小肺结节早期肺癌诊断的附加价值:一项配对病例对照研究
在NLST低剂量CT队列中选取186例4-20mm非钙化肺结节且接受活检的参与者进行配对病例对照研究,验证集上CAD的AUC为0.9154,CAD与三位放射科医生联合阅片的敏感度、特异度、PPV、NPV分别为0.95、0.88、0.86、0.96和0.70、0.69、0.64、0.75,CAD可提高PPV并降低假阳性率。
要点
- CAD在验证集AUC为0.9154,敏感度0.95、特异度0.88、PPV 0.86、NPV 0.96。
- 三位胸科放射科医生联合阅片敏感度0.70、特异度0.69、PPV 0.64、NPV 0.75。
- NLST研究者的敏感度1.00、特异度0.00、PPV 0.43。
核心结论
- CAD可提高早期肺癌诊断的PPV并降低假阳性率。
研究设计与样本
- 配对病例对照研究,样本为NLST中186例4-20mm非钙化肺结节且接受活检的参与者,按年龄、性别、吸烟状态、COPD状态、BMI、阳性筛查检查的研究年份和筛查结果配对。
诊断标准与关键数值
- 验证集CAD的AUC为0.9154;CAD敏感度0.95、特异度0.88、PPV 0.86、NPV 0.96。
- 三位胸科放射科医生联合阅片敏感度0.70、特异度0.69、PPV 0.64、NPV 0.75。
- NLST研究者敏感度1.00、特异度0.00、PPV 0.43。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To test whether computer-aided diagnosis (CAD) approaches can increase the positive predictive value (PPV) and reduce the false-positive rate in lung cancer screening for small nodules compared with human reading by thoracic radiologists. Materials and Methods A matched case-control sample of low-dose computed tomography (CT) studies in 186 participants with 4-20-mm noncalcified lung nodules who underwent biopsy in the National Lung Screening Trial (NLST) was selected. Variables used for matching were age, sex, smoking status, chronic obstructive pulmonary disease status, body mass index, study year of the positive screening test, and screening results. Studies before lung biopsy were randomly split into a training set (70 cancers plus 70 benign controls) and a validation set (20 cancers plus 26 benign controls). Image features from within and outside dominant nodules were extracted. A CAD algorithm developed from the training set and a random forest classifier were applied to the validation set to predict biopsy outcomes. Receiver operating characteristic analysis was used to compare the prediction accuracy of CAD with the NLST investigator's diagnosis and readings from three experienced and board-certified thoracic radiologists who used contemporary clinical practice guidelines. Results In the validation cohort, the area under the receiver operating characteristic curve for CAD was 0.9154. By default, the sensitivity, specificity, and PPV of the NLST investigators were 1.00, 0.00, and 0.43, respectively. The sensitivity, specificity, PPV, and negative predictive value of CAD and the three radiologists' combined reading were 0.95, 0.88, 0.86, and 0.96 and 0.70, 0.69, 0.64, and 0.75, respectively. Conclusion CAD could increase PPV and reduce the false-positive rate in the early diagnosis of lung cancer. © RSNA, 2017 Online supplemental material is available for this article.
引用
- Huang P, Park S, Yan R, et al. Added Value of Computer-aided CT Image Features for Early Lung Cancer Diagnosis with Small Pulmonary Nodules: A Matched Case-Control Study. Radiology. 2017. PMID: 28872442. doi:10.1148/radiol.2017162725
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。