文献速递胸部介入CT

CT引导下≤8 mm肺结节空心针活检的诊断可行性与安全性:单机构经验

Diagnostic feasibility and safety of CT-guided core biopsy for lung nodules less than or equal to 8 mm: A single-institution experience.
PubMed 文献 · Eur Radiol · 2017-09-07

本回顾性研究评估了CT引导下≤8 mm肺结节空心针活检的诊断率与安全性,共125个≤8 mm结节,并与134个>8且≤10 mm结节比较。≤8 mm结节敏感度87.1%(61/70)、特异度100%(24/24)、诊断准确率90.4%(85/94);≤6 mm结节非诊断率15.4%(6/39)高于>8且≤10 mm结节的3.7%(5/134,P=0.017)。作者认为CT引导下肺活检对≤8 mm结节可行,尤其是>6 mm者。

要点

  • ≤8 mm肺结节CT引导空心针活检诊断准确率90.4%(85/94),敏感度87.1%(61/70),特异度100%(24/24)。
  • ≤6 mm结节非诊断率15.4%(6/39),高于>8且≤10 mm结节的3.7%(5/134,P=0.017)。
  • 非胸膜下结节和高龄是更高级别出血的危险因素。

核心结论

  • CT引导下肺活检对≤8 mm肺结节可行,尤其是>6 mm者,具有可接受的诊断率和安全性。

研究设计与样本

  • 回顾性研究,纳入125个≤8 mm肺结节行CT引导下空心针活检,并与134个>8且≤10 mm肺结节比较;病理诊断由组织病理学检查和压印细胞学联合做出。

诊断标准与关键数值

  • ≤8 mm结节:敏感度87.1%(61/70)、特异度100%(24/24)、诊断准确率90.4%(85/94);诊断失败率≤8 mm为9.6%(9/94),>8且≤10 mm为6.3%(7/111),P=0.385;≤8 mm结节胸腔置管率1.6%,>8且≤10 mm为0.7%,P=0.611;≤6 mm结节非诊断率15.4%(6/39),>8且≤10 mm为3.7%(5/134),P=0.017。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This retrospective study evaluated the diagnostic yield and safety of CT-guided core biopsy of pulmonary nodules ≤8 mm.

METHODS: We determined the diagnostic yield and safety profile of CT-guided lung biopsies for 125 pulmonary nodules ≤8 mm. Pathological diagnoses were made by a combination of histopathological examination and imprint cytology. Results were compared with biopsy results for 134 pulmonary nodules >8 and ≤10 mm.

RESULTS: Final diagnoses were established in 94 nodules ≤8 mm. The sensitivity, specificity and diagnostic accuracy of CT-guided core biopsy for nodules ≤8 mm were 87.1 % (61/70 nodules), 100 % (24/24) and 90.4 % (85/94), respectively. Diagnostic failure rates were comparable for nodules ≤8 mm and nodules >8 mm and ≤10 mm (9/94, 9.6 % and 7/111, 6.3 %, respectively, P=0.385). The rate of tube thoracostomy for nodules ≤8 mm was comparable to that for nodules >8 and ≤10 mm (1.6 % vs. 0.7 %, P=0.611). Nodules ≤6 mm had a higher non-diagnostic result rate of 15.4 % (6/39) than did nodules >8 and ≤10 mm (3.7 %, 5/134, P=0.017).

CONCLUSIONS: CT-guided pulmonary biopsy is feasible for lung nodules ≤8 mm, especially those >6 mm, and has an acceptable diagnostic yield and safety profile.

KEY POINTS: • CT-guided biopsy of lung nodules ≤8 mm has high diagnostic accuracy. • Safety profiles are similar between nodules ≤8 mm and 8-10 mm. • Nodules ≤6 mm have higher rates of non-diagnostic results in biopsy. • Non-subpleural nodules and old age are risk factors for higher grade haemorrhage. • Biopsy is feasible for diagnosing nodules >6 and ≤8 mm.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Chang YY, Chen CK, Yeh YC, et al. Diagnostic feasibility and safety of CT-guided core biopsy for lung nodules less than or equal to 8 mm: A single-institution experience. Eur Radiol. 2017. PMID: 28884222. doi:10.1007/s00330-017-5027-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。