联合心电与呼吸触发CT减少自由呼吸儿童肺部成像层块间呼吸配准伪影的初步经验
本研究纳入15例自由呼吸儿童,比较心电触发联合呼吸触发与单纯心电触发肺部CT的呼吸配准伪影。联合触发组伪影评分显著低于单纯心电触发组(1.1 ± 0.4 vs. 2.2 ± 1.0,p = 0.003)。结论:附加呼吸触发可减少心电触发肺部CT的呼吸配准伪影。
要点
- 自由呼吸儿童心电触发肺部CT联合呼吸触发可减少层块间呼吸配准伪影。
- 联合触发组伪影评分1.1 ± 0.4,显著低于单纯心电触发组2.2 ± 1.0(p = 0.003)。
- 伪影按4分制评分(1分为图像质量极佳),在冠状位和矢状位图像上评估。
核心结论
- 在自由呼吸儿童中,心电触发肺部CT附加呼吸触发可减少层块间呼吸配准伪影。
研究设计与样本
- 初步经验研究,纳入15例自由呼吸儿童(中位年龄19个月,范围6个月至8岁;7例男孩),均接受心电触发肺部CT联合和不联合呼吸触发检查;使用呼吸门控系统的压力传感带获取呼吸信号;在冠状位和矢状位图像上按4分制(1分为图像质量极佳)评估层块间呼吸配准伪影程度,p值小于0.05认为有统计学意义。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children.
MATERIALS AND METHODS: In total, 15 children (median age 19 months, range 6 months-8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant.
RESULTS: Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003).
CONCLUSION: Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children.
引用
- Goo HW, Allmendinger T. Combined Electrocardiography- and Respiratory-Triggered CT of the Lung to Reduce Respiratory Misregistration Artifacts between Imaging Slabs in Free-Breathing Children: Initial Experience. Korean J Radiol. 2017. PMID: 28860904. doi:10.3348/kjr.2017.18.5.860
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。