文献速递甲状腺与浅表头颈US

定量超声造影指标鉴别甲状腺良恶性实性结节的诊断效能

Diagnostic Efficiency of Quantitative Contrast-Enhanced Ultrasound Indicators for Discriminating Benign From Malignant Solid Thyroid Nodules.
PubMed 文献 · J Ultrasound Med · 2017-09-07

研究纳入167例经手术或细针穿刺确诊的甲状腺孤立结节患者,采集结节及结节周围区域的定量超声造影指标并行单因素和多因素logistic回归及ROC曲线分析。结果显示结节与结节周围峰值强度比值诊断效能最佳,敏感度80.41%、特异度80.00%。定量超声造影指标有助于鉴别甲状腺结节良恶性。

要点

  • 结节与结节周围峰值强度比值诊断效能最佳,敏感度80.41%、特异度80.00%。
  • 结节区域低峰值强度、低上升斜率、低曲线下面积及高下降斜率提示恶性。
  • 结节周围区域高峰值强度、高上升斜率、高曲线下面积及低下降斜率与恶性相关。

核心结论

  • 定量超声造影指标有助于鉴别甲状腺良恶性结节,其中结节与结节周围峰值强度比值诊断效能最佳。

研究设计与样本

  • 共纳入167例甲状腺孤立结节患者,诊断经手术或细针穿刺证实,采集结节及结节周围区域的定量超声造影指标,行单因素和多因素logistic回归分析并生成ROC曲线。

诊断标准与关键数值

  • 结节峰值强度、上升斜率、下降斜率、曲线下面积的截断值分别为20.75、0.91、-0.2、1818.23。
  • 结节与结节周围峰值强度、上升斜率、下降斜率、曲线下面积比值的截断值分别为0.90、0.95、0.96、0.96。
  • 结节与结节周围峰值强度比值诊断效能最佳,敏感度80.41%、特异度80.00%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: We aimed to determine the most efficient quantitative parameters to establish a contrast-enhanced ultrasound (US) assessment system for distinguishing between benign and malignant thyroid nodules.

METHODS: A total of 167 patients with thyroid solitary nodules had the diagnosis confirmed by surgery or fine-needle aspiration. Quantitative contrast-enhanced US indicators (time to peak, time from peak to one-half, ascend slope, descend slope, peak intensity, and area under the curve [AUC]) were gathered in nodule and perinodule areas. Univariate and multivariate logistic regression analyses were performed. Receiver operating characteristic curves were generated. Sensitivities, specificities, and positive and negative predictive values were calculated to identify the best cutoff value.

RESULTS: The univariate logistic regression model showed that the peak intensity, ascend slope, descend slope, and AUC were significant indicators for discriminating benign from malignant nodules under contrast-enhanced US (P < .0001). For thyroid nodules, low peak intensity, ascend slope, and AUC and high descend slope values were significant indicators of malignancy. However, in perinodule areas, high peak intensity, ascend slope, and AUC and low descend slope values were significantly associated with malignancies. The cutoff values for the nodule peak intensity, ascend slope, descend slope, and AUC were 20.75, 0.91, -0.2, and 1818.23, respectively. The cutoff values for the ratios of the nodule versus perinodule peak intensity, ascend slope, descend slope, and AUC were 0.90, 0.95, 0.96, and 0.96. The nodule-to-perinodule peak intensity ratio showed the best diagnostic efficiency, with 80.41% sensitivity and 80.00% specificity.

CONCLUSIONS: Quantitative contrast-enhanced US indicators help discriminate benign from malignant thyroid nodules. The nodule-to-perinodule peak intensity ratio showed the best diagnostic efficiency.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zhou X, Zhou P, Hu Z, et al. Diagnostic Efficiency of Quantitative Contrast-Enhanced Ultrasound Indicators for Discriminating Benign From Malignant Solid Thyroid Nodules. J Ultrasound Med. 2017. PMID: 28880412. doi:10.1002/jum.14347

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。