文献速递神经MR

多发性硬化:三维T1黑血磁共振成像较传统三维T1梯度回波成像提高活动性脑病灶检出率

Multiple Sclerosis: Improved Detection of Active Cerebral Lesions With 3-Dimensional T1 Black-Blood Magnetic Resonance Imaging Compared With Conventional 3-Dimensional T1 GRE Imaging.
PubMed 文献 · Invest Radiol · 2018-01-01

这项单中心前瞻性队列研究纳入22例复发缓解型多发性硬化患者,对比增强三维T1黑血序列(T1-mVISTA)与常规三维T1磁化准备快速梯度回波(MP-RAGE)序列对强化脑病灶的检出。T1-mVISTA检出强化病灶71个,MP-RAGE检出39个(P < 0.001),且T1-mVISTA的视觉对比增强、对比噪声比和诊断信心均显著提高(P < 0.001)。

要点

  • T1-mVISTA检出强化病灶71个,MP-RAGE检出39个,差异有统计学意义(P < 0.001)。
  • MP-RAGE初次阅片漏诊25.6%病灶,T1-mVISTA仅漏诊4.2%。
  • T1-mVISTA体素从0.8 mm增至1.0 mm各向同性未影响病灶检出,扫描时间由4分43秒缩短至1分55秒。

核心结论

  • 三维T1-mVISTA通过提高病灶对比噪声比,较传统三维MP-RAGE提高对比增强多发性硬化脑病灶的检出率,可能有助于患者管理。

研究设计与样本

  • 单中心前瞻性队列研究,纳入22例复发缓解型多发性硬化患者(8例男性,年龄31.0 ± 9.2岁),对比增强T1-mVISTA与MP-RAGE分辨率均为0.8 mm,参考标准由经验丰富的神经放射科医生综合所有可用序列定义。

关键影像表现/征象

  • T1-mVISTA上对比增强多发性硬化病灶的视觉对比增强、对比噪声比和诊断信心均较MP-RAGE显著提高(P < 0.001)。
  • 22例患者中11例显示对比增强病灶。
  • T1-mVISTA检出强化病灶71个,MP-RAGE检出39个,T1-mVISTA检出显著更多(P < 0.001)。

诊断标准与关键数值

  • 以经验丰富的神经放射科医生综合所有可用序列定义的病灶为参考标准。
  • T1-mVISTA检出强化病灶71个 vs MP-RAGE检出39个(P < 0.001)。
  • MP-RAGE初次阅片漏诊25.6%病灶,T1-mVISTA漏诊4.2%。
  • 12例亚研究中,T1-mVISTA体素从0.8 mm增至1.0 mm各向同性未影响病灶检出,扫描时间从4分43秒缩短至1分55秒。

临床应用与阅片要点

  • T1-mVISTA较MP-RAGE提高对比增强多发性硬化脑病灶的对比噪声比和诊断信心,可能有助于患者管理。
  • T1-mVISTA_1.0(1.0 mm各向同性)未影响病灶检出且扫描时间更短。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to assess the diagnostic accuracy of a modified high-resolution whole-brain three-dimensional T1-weighted black-blood sequence (T1-weighted modified volumetric isotropic turbo spin echo acquisition [T1-mVISTA]) in comparison to a standard three-dimensional T1-weighted magnetization-prepared rapid gradient echo (MP-RAGE) sequence for detection of contrast-enhancing cerebral lesions in patients with relapsing-remitting multiple sclerosis (MS).

MATERIALS AND METHODS: After institutional review board approval and informed consent, 22 patients (8 men; aged 31.0 ± 9.2 years) with relapsing-remitting MS were included in this monocentric prospective cohort study.Contrast-enhanced T1-mVISTA and MP-RAGE, both with 0.8 mm resolution, were performed in all patients. In a substudy of 12 patients, T1-mVISTA was compared with a T1-mVISTA with 1.0 mm resolution (T1-mVISTA_1.0). Reference lesions were defined by an experienced neuroradiologist using all available sequences and served as the criterion standard. T1-mVISTA, T1-mVISTA_1.0, and MP-RAGE sequences were read in random order 4 weeks apart. Image quality, visual contrast enhancement, contrast-to-noise-ratio (CNR), diagnostic confidence, and lesion size were assessed and compared by Wilcoxon and Mann-Whitney U tests.

RESULTS: Eleven of 22 patients displayed contrast-enhancing lesions. Visual contrast enhancement, CNR, and diagnostic confidence of contrast-enhancing MS lesions were significantly increased in T1-mVISTA compared with MP-RAGE (P < 0.001). Significantly more contrast-enhancing lesions were detected with T1-mVISTA than with MP-RAGE (71 vs 39, respectively; P < 0.001). With MP-RAGE, 25.6% of lesions were missed in the initial reading, whereas only 4.2% of lesions were missed with T1-mVISTA. Increase of the voxel volume from 0.8 mm to 1.0 mm isotropic in T1-mVISTA_1.0 did not affect the detectability of lesions, whereas scan time was decreased from 4:43 to 1:55 minutes.

CONCLUSIONS: Three-dimensional T1-mVISTA improves the detection rates of contrast-enhancing cerebral MS lesions compared with conventional 3D MP-RAGE sequences by increasing CNR of lesions and might, therefore, be useful in patient management.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Sommer NN, Saam T, Coppenrath E, et al. Multiple Sclerosis: Improved Detection of Active Cerebral Lesions With 3-Dimensional T1 Black-Blood Magnetic Resonance Imaging Compared With Conventional 3-Dimensional T1 GRE Imaging. Invest Radiol. 2018. PMID: 28858894. doi:10.1097/RLI.0000000000000410

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。