使用患者特异性计算模型评估妊娠女性及胎儿的CT剂量
基于标准化混合计算孕妇体模构建患者特异性体素模型,估算30例在日内瓦大学医院急诊行腹部CT的孕妇的母体吸收剂量与胎儿器官剂量;母体有效剂量平均1.6 mSv,胎儿剂量归一化CTDIvol平均1.17,胎儿器官剂量分布不均匀,胎儿脑与骨骼剂量与孕龄显著相关。
要点
- 母体有效剂量平均1.6 mSv(范围1.1–2.0 mSv),商用剂量追踪软件报告平均1.9 mSv(范围1.7–2.3 mSv)。
- 胎儿剂量归一化CTDIvol在0.85至1.63之间,平均1.17。
- 胎儿脑和骨骼剂量与孕龄呈显著相关。
核心结论
- 构建个性化计算模型的方法可用于估算CT检查中患者特异性辐射剂量,剂量学数据可用于评估不同CT扫描方案对孕妇和胎儿的辐射风险,从而指导决策过程。
研究设计与样本
- 基于现有标准化混合计算孕妇体模构建患者特异性体素计算体模的方法学研究,对30例转诊至日内瓦大学医院急诊行腹部CT的孕妇估算母体吸收剂量和胎儿器官剂量。
关键影像表现/征象
- CT检查中胎儿器官内吸收剂量呈非均匀分布。
- 胎儿脑和骨骼剂量与孕龄呈显著相关。
诊断标准与关键数值
- 母体有效剂量范围1.1–2.0 mSv,平均1.6 mSv。
- 商用剂量追踪软件报告平均有效剂量1.9 mSv(范围1.7–2.3 mSv)。
- 胎儿剂量归一化CTDIvol范围0.85–1.63,平均1.17。
临床应用与阅片要点
- 所建方法学适用于患者特异性CT辐射剂量估算。
- 剂量学数据可用于评估不同CT扫描方案对孕妇和胎儿的辐射风险,指导决策过程。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This work provides detailed estimates of the foetal dose from diagnostic CT imaging of pregnant patients to enable the assessment of the diagnostic benefits considering the associated radiation risks.
MATERIALS AND METHODS: To produce realistic biological and physical representations of pregnant patients and the embedded foetus, we developed a methodology for construction of patient-specific voxel-based computational phantoms based on existing standardised hybrid computational pregnant female phantoms. We estimated the maternal absorbed dose and foetal organ dose for 30 pregnant patients referred to the emergency unit of Geneva University Hospital for abdominal CT scans.
RESULTS: The effective dose to the mother varied from 1.1 mSv to 2.0 mSv with an average of 1.6 mSv, while commercial dose-tracking software reported an average effective dose of 1.9 mSv (range 1.7-2.3 mSv). The foetal dose normalised to CTDIvol varies between 0.85 and 1.63 with an average of 1.17.
CONCLUSION: The methodology for construction of personalised computational models can be exploited to estimate the patient-specific radiation dose from CT imaging procedures. Likewise, the dosimetric data can be used for assessment of the radiation risks to pregnant patients and the foetus from various CT scanning protocols, thus guiding the decision-making process.
KEY POINTS: • In CT examinations, the absorbed dose is non-uniformly distributed within foetal organs. • This work reports, for the first time, estimates of foetal organ-level dose. • The foetal brain and skeleton doses present significant correlation with gestational age. • The conceptus dose normalised to CTDI vol varies between 0.85 and 1.63. • The developed methodology is adequate for patient-specific CT radiation dosimetry.
引用
- Xie T, Poletti PA, Platon A, et al. Assessment of CT dose to the fetus and pregnant female patient using patient-specific computational models. Eur Radiol. 2017. PMID: 28887589. doi:10.1007/s00330-017-5000-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。