栓塞性犬卒中模型中体素内不相干运动磁共振成像衍生指标与血清可溶性CD40配体水平的相关性
在24只比格犬大脑中动脉闭塞模型中,于造模后4.5小时行IVIM成像并测血清sCD40L,按sCD40L水平分为低、高两组。高sCD40L组f值及标准化f值显著低于低sCD40L组,且f值与sCD40L水平呈负相关;D、D*及其标准化值组间无显著差异且与sCD40L无显著相关。作者认为f值可能作为评估缺血性卒中超急性期微血管血栓形成的影像生物标志物。
要点
- 高sCD40L组f值及标准化f值均显著低于低sCD40L组(均p<0.001)。
- f值与标准化f值均与血清sCD40L水平呈负相关(r=-0.789与r=-0.823,均p<0.001)。
- D、D*及其标准化值与sCD40L水平无显著相关(均p>0.05)。
核心结论
- IVIM成像衍生的f值与血清sCD40L水平呈负相关,作者认为f值可能作为评估缺血性卒中超急性期微血管血栓形成的潜在影像生物标志物。
研究设计与样本
- 在24只比格犬中建立大脑中动脉闭塞模型,于造模后4.5小时按血清sCD40L水平分为低sCD40L组和高sCD40L组;行IVIM成像,b值取0至900 s/mm2共10个,计算缺血灶的D、D*和f值,并以对侧半球标准化(标准化D=D卒中/D对侧);组间比较用t检验,相关性用Pearson分析。
诊断标准与关键数值
- 高sCD40L组f值低于低sCD40L组(p<0.001),标准化f值亦低于低sCD40L组(p<0.001);D*、标准化D*、D、标准化D组间均无显著差异(均p>0.05);f值与血清sCD40L水平负相关(r=-0.789,p<0.001),标准化f值与血清sCD40L水平负相关(r=-0.823,p<0.001);D*、标准化D*、D、标准化D与血清sCD40L水平均无显著相关(均p>0.05)。
临床应用与阅片要点
- 作者认为IVIM衍生的f值可能作为评估缺血性卒中超急性期微血管血栓形成的潜在影像生物标志物。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine the relationship between intravoxel incoherent motion (IVIM) imaging derived quantitative metrics and serum soluble CD40 ligand (sCD40L) level in an embolic canine stroke model.
MATERIALS AND METHODS: A middle cerebral artery occlusion model was established in 24 beagle dogs. Experimental dogs were divided into low- and high-sCD40L group according to serum sCD40L level at 4.5 hours after establishing the model. IVIM imaging was scanned at 4.5 hours after model establishment using 10 b values ranging from 0 to 900 s/mm2. Quantitative metrics diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) of ischemic lesions were calculated. Quantitative metrics of ischemic lesions were normalized by contralateral hemisphere using the following formula: normalized D = Dstroke / Dcontralateral. Differences in IVIM metrics between the low- and high-sCD40L groups were compared using t test. Pearson's correlation analyses were performed to determine the relationship between IVIM metrics and serum sCD40L level.
RESULTS: The high-sCD40L group showed significantly lower f and normalized f values than the low-sCD40L group (f, p < 0.001; normalized f, p < 0.001). There was no significant difference in D*, normalized D*, D, or normalized D value between the two groups (All p > 0.05). Both f and normalized f values were negatively correlated with serum sCD40L level (f, r = -0.789, p < 0.001; normalized f, r = -0.823, p < 0.001). However, serum sCD40L level had no significant correlation with D*, normalized D*, D, or normalized D (All p > 0.05).
CONCLUSION: The f value derived from IVIM imaging was negatively correlated with serum sCD40L level. f value might serve as a potential imaging biomarker to assess the formation of microvascular thrombosis in hyperacute period of ischemic stroke.
引用
- Xu XQ, Wu CJ, Lu SS, et al. Correlation between Intravoxel Incoherent Motion Magnetic Resonance Imaging Derived Metrics and Serum Soluble CD40 Ligand Level in an Embolic Canine Stroke Model. Korean J Radiol. 2017. PMID: 28860901. doi:10.3348/kjr.2017.18.5.835
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。