文献速递神经MR

基于雅可比算子场的半自动算法在纵向MRI中检测体积变化的转移性脑肿瘤

Detection of Volume-Changing Metastatic Brain Tumors on Longitudinal MRI Using a Semiautomated Algorithm Based on the Jacobian Operator Field.
PubMed 文献 · AJNR Am J Neuroradiol · 2017-09-07

本研究使用50对连续脑MRI数据集(30对1.5T、20对3T,含增强3D T1加权序列),共150个增大或缩小的转移性脑肿瘤,开发并评估基于雅可比算子场的半自动算法检测体积变化肿瘤的准确性。ROC分析显示1.5T和3T的AUC分别为0.925和0.965,最佳性能时敏感度分别为85.1%和92.1%、特异度分别为86.7%和91.3%。血管是主要假阳性来源,新发或消退的转移瘤是主要假阴性来源。

要点

  • 算法在3T MRI上检测体积变化转移瘤的AUC为0.965,优于1.5T的0.925。
  • 最佳性能时敏感度1.5T为85.1%、3T为92.1%,特异度1.5T为86.7%、3T为91.3%。
  • 血管是假阳性的主要原因,新发或消退的转移瘤是假阴性的主要来源。

核心结论

  • 所提出的算法能以统计学上高的准确度在纵向脑MRI上检测体积变化的转移性脑肿瘤,展示其作为计算机辅助变化检测工具的潜力,可补充放射科医生的表现、减少观察者间和观察者内变异并提高效率。

研究设计与样本

  • 开发并评估半自动算法的研究;使用50对连续MR成像数据集,其中30对在1.5T、20对在3T,包含增强3D T1加权序列;共产生150个增大或缩小的转移性脑肿瘤;参考标准基于一位神经放射科医生的检测;采用ROC分析评估检测准确度,并用jackknife重采样验证。

诊断标准与关键数值

  • 1.5T的ROC曲线下面积为0.925,3T为0.965;最佳性能时,1.5T敏感度85.1%、特异度86.7%,3T敏感度92.1%、特异度91.3%。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 血管是大多数假阳性的原因;新发或消退的转移性脑肿瘤是假阴性的主要来源。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Accurate follow-up of metastatic brain tumors has important implications for patient prognosis and management. The aim of this study was to develop and evaluate the accuracy of a semiautomated algorithm in detecting growing or shrinking metastatic brain tumors on longitudinal brain MRIs.

MATERIALS AND METHODS: We used 50 pairs of successive MR imaging datasets, 30 on 1.5T and 20 on 3T, containing contrast-enhanced 3D T1-weighted sequences. These yielded 150 growing or shrinking metastatic brain tumors. To detect them, we completed 2 major steps: 1) spatial normalization and calculation of the Jacobian operator field to quantify changes between scans, and 2) metastatic brain tumor candidate segmentation and detection of volume-changing metastatic brain tumors with the Jacobian operator field. Receiver operating characteristic analysis was used to assess the detection accuracy of the algorithm, and it was verified with jackknife resampling. The reference standard was based on detections by a neuroradiologist.

RESULTS: The areas under the receiver operating characteristic curves were 0.925 for 1.5T and 0.965 for 3T. Furthermore, at its optimal performance, the algorithm achieved a sensitivity of 85.1% and 92.1% and specificity of 86.7% and 91.3% for 1.5T and 3T, respectively. Vessels were responsible for most false-positives. Newly developed or resolved metastatic brain tumors were a major source of false-negatives.

CONCLUSIONS: The proposed algorithm could detect volume-changing metastatic brain tumors on longitudinal brain MRIs with statistically high accuracy, demonstrating its potential as a computer-aided change-detection tool for complementing the performance of radiologists, decreasing inter- and intraobserver variability, and improving efficacy.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Shearkhani O, Khademi A, Eilaghi A, et al. Detection of Volume-Changing Metastatic Brain Tumors on Longitudinal MRI Using a Semiautomated Algorithm Based on the Jacobian Operator Field. AJNR Am J Neuroradiol. 2017. PMID: 28882862. doi:10.3174/ajnr.A5352

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。