文献速递神经介入MR

实时运动皮层定位用于胶质瘤安全切除:一项术中静息态fMRI研究

Real-Time Motor Cortex Mapping for the Safe Resection of Glioma: An Intraoperative Resting-State fMRI Study.
PubMed 文献 · AJNR Am J Neuroradiol · 2017-09-07

研究利用介入性MRI对30例脑肿瘤患者行术前及术中静息态功能连接分析,其中14例完成足够术中静息态fMRI及直接皮层电刺激者用于分析,术中静息态fMRI定位运动区的敏感度为61.7%、特异度为93.7%;肿瘤腔填充生理盐水时图像质量更优(P = .049),麻醉类型间无显著差异(P = .102)。

要点

  • 术中静息态fMRI定位运动区敏感度61.7%、特异度93.7%,以直接皮层电刺激为参考。
  • 肿瘤腔填充生理盐水时术中静息态fMRI图像质量优于未填充(P = .049)。
  • 全身麻醉与清醒麻醉间术中静息态fMRI图像质量无显著差异(P = .102)。

核心结论

  • 研究显示术中静息态fMRI用于神经外科手术中实时定位功能区具有可行性,可能避免直接皮层电刺激所致术中癫痫风险,并可能为神经外科医生提供有助于胶质瘤安全切除的信息。

研究设计与样本

  • 采用介入性MRI的前瞻性术中影像研究,纳入30例脑肿瘤患者行术前及术中静息态内在功能连接分析,以直接皮层电刺激验证运动皮层定位准确性,14例完成足够术中静息态fMRI及直接皮层电刺激者用于敏感度与特异度分析。

关键影像表现/征象

  • 术中静息态fMRI可实时显示运动皮层功能连接,用于术中运动区定位。
  • 肿瘤腔填充生理盐水时术中静息态fMRI图像质量优于未填充(P = .049)。
  • 全身麻醉与清醒麻醉间术中静息态fMRI图像质量无显著差异(P = .102)。

诊断标准与关键数值

  • 以直接皮层电刺激为参考,术中静息态fMRI定位运动区的敏感度为61.7%、特异度为93.7%(14例完成足够术中静息态fMRI及直接皮层电刺激者)。

临床应用与阅片要点

  • 术中静息态fMRI可用于神经外科手术中实时定位运动皮层,可能为胶质瘤安全切除提供信息。
  • 术中成像时肿瘤腔填充生理盐水可能获得更好的静息态fMRI图像质量。
  • 术中静息态fMRI定位运动区敏感度61.7%、特异度93.7%,阅片判读需结合直接皮层电刺激等参考标准。

局限性

  • 原文结论指出本研究为可行性研究,需进一步研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Resting-state functional MR imaging has been used for motor mapping in presurgical planning but never used intraoperatively. This study aimed to investigate the feasibility of applying intraoperative resting-state functional MR imaging for the safe resection of gliomas using real-time motor cortex mapping during an operation.

MATERIALS AND METHODS: Using interventional MR imaging, we conducted preoperative and intraoperative resting-state intrinsic functional connectivity analyses of the motor cortex in 30 patients with brain tumors. Factors that may influence intraoperative imaging quality, including anesthesia type (general or awake anesthesia) and tumor cavity (filled with normal saline or not), were studied to investigate image quality. Additionally, direct cortical stimulation was used to validate the accuracy of intraoperative resting-state fMRI in mapping the motor cortex.

RESULTS: Preoperative and intraoperative resting-state fMRI scans were acquired for all patients. Fourteen patients who successfully completed both sufficient intraoperative resting-state fMRI and direct cortical stimulation were used for further analysis of sensitivity and specificity. Compared with those subjected to direct cortical stimulation, the sensitivity and specificity of intraoperative resting-state fMRI in localizing the motor area were 61.7% and 93.7%, respectively. The image quality of intraoperative resting-state fMRI was better when the tumor cavity was filled with normal saline (P = .049). However, no significant difference between the anesthesia types was observed (P = .102).

CONCLUSIONS: This study demonstrates the feasibility of using intraoperative resting-state fMRI for real-time localization of functional areas during a neurologic operation. The findings suggest that using intraoperative resting-state fMRI can avoid the risk of intraoperative seizures due to direct cortical stimulation and may provide neurosurgeons with valuable information to facilitate the safe resection of gliomas.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Qiu TM, Gong FY, Gong X, et al. Real-Time Motor Cortex Mapping for the Safe Resection of Glioma: An Intraoperative Resting-State fMRI Study. AJNR Am J Neuroradiol. 2017. PMID: 28882861. doi:10.3174/ajnr.A5369

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。