低剖面编织支架血流导向治疗Willis环附近或远端极小或无法弹簧圈栓塞的颅内动脉瘤
回顾性分析19例患者20个位于Willis环或远端、不适合弹簧圈栓塞的动脉瘤,采用低剖面编织支架行单纯支架置入术。平均随访14.7个月,完全闭塞率73.7%,套叠双支架组完全闭塞率81.8%,技术成功率95%,技术并发症和迟发性缺血事件各1例(5.3%)。
要点
- 低剖面编织支架单纯置入治疗Willis环或远端极小或无法栓塞动脉瘤技术成功率95%。
- 平均随访14.7个月完全闭塞率73.7%,套叠双支架置入者完全闭塞率81.8%。
- 技术并发症和迟发性缺血事件各1例(5.3%),末次随访mRS评分均为0-2分。
核心结论
- 低剖面编织支架作为单纯支架置入行血流导向治疗Willis环或远端极小或无法弹簧圈栓塞的颅内动脉瘤是一种有前景、相对安全且持久的血管内治疗方法。
研究设计与样本
- 回顾性研究,纳入19例患者共20个位于Willis环或远端的动脉瘤,均采用低剖面编织支架行单纯支架置入术;评估即刻和随访血管造影结果及临床状态。
诊断标准与关键数值
- 动脉瘤平均大小为4.7 ± 2.4 mm。
- 11个动脉瘤采用套叠置入2枚支架,其余动脉瘤采用单支架置入。
- 技术成功率为95%。
- 平均随访14.7个月,最终血管造影显示完全闭塞率为73.7%;套叠支架置入治疗的动脉瘤完全闭塞率为81.8%。
- 末次随访时所有患者改良Rankin量表评分为0至2分。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The endovascular treatment of aneurysms located at or distal to the circle of Willis and not amenable to coiling remains a challenge. We report our experience with flow-diversion treatment using low-profile braided stents as a stent monotherapy procedure for treating distally located very small or uncoilable aneurysms.
MATERIALS AND METHODS: We retrospectively reviewed our data bases to identify patients with aneurysms located at or distal to the circle of Willis who were treated with stent monotherapy using low-profile braided stents. The immediate and follow-up angiographic findings and clinical status of the patients were assessed.
RESULTS: Twenty aneurysms in 19 patients were included in the study. The mean size of the aneurysms was 4.7 ± 2.4 mm. Patients were treated via telescopic implantation of 2 stents for 11 aneurysms; single-stent placement was used for the remaining aneurysms. The technical success rate was 95%. We observed a technical complication in 1 case (5.3%) and a late ischemic event in another (5.3%). The final angiographies during a mean follow-up of 14.7 months showed complete aneurysm occlusion in 73.7%. The complete occlusion rate of the aneurysms treated with telescopic stent placement was 81.8%. The modified Rankin scale scores of all patients at the last follow-up were between 0 and 2.
CONCLUSIONS: Flow diversion with low-profile braided stents as a stent monotherapy procedure for very small or uncoilable intracranial aneurysms located at or beyond the circle of Willis is a promising, relatively safe, and durable endovascular procedure.
引用
- Aydin K, Barburoglu M, Sencer S, et al. Flow Diversion with Low-Profile Braided Stents for the Treatment of Very Small or Uncoilable Intracranial Aneurysms at or Distal to the Circle of Willis. AJNR Am J Neuroradiol. 2017. PMID: 28882859. doi:10.3174/ajnr.A5362
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。