Woven EndoBridge 治疗破裂颅内动脉瘤:单中心 100 例队列
2015年2月至2017年4月单中心对100例破裂颅内动脉瘤行Woven EndoBridge囊内治疗,未使用支架或球囊辅助。治疗相关死亡/致残率为4%,80例可评估患者中74例完成3个月造影随访,完全闭塞占73%,总再通/再治疗率为6.8%,随访期无再出血。作者结论认为Woven EndoBridge治疗小型破裂动脉瘤安全有效,可作为无需支架或球囊的弹簧圈替代方案。
要点
- Woven EndoBridge可治疗破裂颅内动脉瘤,66%为宽颈(≥4 mm或瘤顶瘤颈比≤1.5)。
- 治疗相关死亡/致残率4%,血栓栓塞并发症9%,术中破裂1例且无后遗症。
- 3个月随访完全闭塞率73%,再通/再治疗率6.8%,随访期无再出血。
核心结论
- 作者结论认为Woven EndoBridge治疗小型破裂动脉瘤安全有效,是无需支架或球囊的弹簧圈替代方案。
研究设计与样本
- 单中心队列研究,2015年2月至2017年4月连续选择性治疗100例破裂颅内动脉瘤,均使用Woven EndoBridge,未使用支架或球囊辅助;患者中女性71例,平均年龄59岁,中位年龄60岁,年龄范围23-82岁。
关键影像表现/征象
- 动脉瘤平均大小为5.6 mm(范围3-13 mm),其中42个动脉瘤≤4 mm。
- 66个动脉瘤(66%)为宽颈,定义为瘤颈≥4 mm或瘤顶瘤颈比≤1.5。
- 9例(9%)发生血栓栓塞并发症;1例术中破裂且无后遗症。
诊断标准与关键数值
- 宽颈定义:瘤颈≥4 mm或瘤顶瘤颈比≤1.5,66个动脉瘤(66%)符合。
- 3个月造影随访:54个动脉瘤(73%)完全闭塞,17个(23%)瘤颈小残留,3个(4%)不完全闭塞。
- 治疗相关死亡/致残率4%(4/100;95%CI 1.2%-10.2%);再通/再治疗率6.8%(5/74;95%CI 2.6%-15.2%)。
临床应用与阅片要点
- 本组对破裂动脉瘤无论位置或瘤颈大小均单独使用Woven EndoBridge,未用支架或球囊辅助。
- 治疗相关死亡/致残率为4%,血栓栓塞并发症为9%,术中破裂1例且无后遗症。
- 80例可评估患者中74例(93%)完成3个月造影随访,完全闭塞54个(73%),瘤颈小残留17个(23%),不完全闭塞3个(4%)。
- 100个动脉瘤中2个初始不完全闭塞并于初次干预后早期追加治疗;1例追加第二枚Woven EndoBridge,2例计划追加治疗。
- 随访期无再出血。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The Woven EndoBridge device was recently introduced for the intrasaccular treatment of wide-neck aneurysms without the need for adjunctive devices. We present our results of the primary treatment of ruptured aneurysms with the Woven EndoBridge regardless of location or neck size.
MATERIALS AND METHODS: Between February 2015 and April 2017, 100 ruptured aneurysms were selectively treated with the Woven EndoBridge. No supporting stents or balloons were used. There were 71 women treated (mean patient age, 59 years; median age, 60 years; range, 23-82 years).
RESULTS: The mean aneurysm size was 5.6 mm (range, 3-13 mm), and 42 aneurysms were ≤4 mm. Sixty-six aneurysms (66%) had a wide neck, defined as ≥4 mm or a dome-neck ratio ≤1.5. There was 1 procedural rupture without sequelae. In 9 patients (9%), thromboembolic complications occurred. One poor grade patient died; neurologic deficits remained in 3. Overall treatment-related morbidity-mortality was 4% (4 of 100; 95% CI, 1.2%-10.2%).Two of 100 aneurysms were initially incompletely occluded and were additionally treated early after initial intervention. Of 80 eligible patients, 74 (93%) had 3-month angiographic follow-up. Fifty-four aneurysms (73%) were completely occluded, 17 (23%) had a small neck remnant, and 3 (4%) were incompletely occluded. One patient was additionally treated with a second Woven EndoBridge, and in 2 patients, additional treatment is scheduled. The overall reopening/retreatment rate was 6.8% (5 of 74; 95% CI, 2.6%-15.2%). There were no rebleeds during follow-up.
CONCLUSIONS: Treatment of small ruptured aneurysms with the Woven EndoBridge was safe and effective. The Woven EndoBridge proved to be a valuable alternative to coils without the need for stents or balloons.
引用
- van Rooij SBT, van Rooij WJ, Peluso JP, et al. WEB Treatment of Ruptured Intracranial Aneurysms: A Single-Center Cohort of 100 Patients. AJNR Am J Neuroradiol. 2017. PMID: 28882858. doi:10.3174/ajnr.A5371
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。