文献速递神经儿科影像MR

儿童脑肿瘤的灌注磁共振成像

Perfusion magnetic resonance imaging in pediatric brain tumors.
PubMed 文献 · Neuroradiology · 2017-08-31

回顾性分析30例接受DSC-MR灌注序列的脑肿瘤患儿,在高、低级别组间比较基于直方图的灌注与渗透性参数并行ROC分析。结果显示平均rCBV、rCBF及PSR在两组间差异有统计学意义,K2/PSR比值判别力强;rCBV与rCBF的ROC AUC均大于0.9,均值阈值分别为1.07和1.03。

要点

  • 儿童脑肿瘤DSC-MR灌注中,高、低级别组间平均rCBV与rCBF差异有统计学意义(p<10-3)。
  • K2/PSR比值在缩减ROI上判别高低级别病变能力强,ROC AUC大于0.9。
  • PSR在两组间差异有统计学意义(p=0.03),而K2因子差异无统计学意义(p=0.5)。

核心结论

  • 采用动态T2*灌注序列并以客观的全病灶ROI分析,可获得可靠结果;灌注参数及新的渗透性指标能有效判别儿童高级别与低级别脑肿瘤。

研究设计与样本

  • 回顾性研究,纳入30例接受DSC-MR灌注序列的脑肿瘤患儿;在覆盖病灶最大的ROI上计算相对CBF与CBV,并在全病灶ROI及渗透性图上缩减ROI评估PSR与K2模型参数。

关键影像表现/征象

  • 高、低级别组间平均rCBV差异有统计学意义(p<10-3)。
  • 高、低级别组间rCBF差异有统计学意义(p<10-3)。
  • 高、低级别组间PSR差异有统计学意义(p=0.03)。
  • 高、低级别组间K2因子差异无统计学意义(p=0.5)。

诊断标准与关键数值

  • rCBV的ROC AUC大于0.9,均值阈值为1.07。
  • rCBF的ROC AUC大于0.9,均值阈值为1.03。
  • 缩减ROI上K2/PSR的ROC AUC大于0.9。
  • 高、低级别组间K2/PSR比值差异有统计学意义(p<10-3)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The use of DSC-MR imaging in pediatric neuroradiology is gradually growing. However, the number of studies listed in the literature remains limited. We propose to assess the perfusion and permeability parameters in pediatric brain tumor grading.

METHODS: Thirty children with a brain tumor having benefited from a DSC-MR perfusion sequence have been retrospectively explored. Relative CBF and CBV were computed on the ROI with the largest lesion coverage. Assessment of the lesion's permeability was also performed through the semi-quantitative PSR parameter and the K2 model-based parameter on the whole-lesion ROI and a reduced ROI drawn on the permeability maps. A statistical comparison of high- and low-grade groups (HG, LG) as well as a ROC analysis was performed on the histogram-based parameters.

RESULTS: Our results showed a statistically significant difference between LG and HG groups for mean rCBV (p < 10-3), rCBF (p < 10-3), and for PSR (p = 0.03) but not for the K2 factor (p = 0.5). However, the ratio K2/PSR was shown to be a strong discriminating factor between the two groups of lesions (p < 10-3). For rCBV and rCBF indicators, high values of ROC AUC were obtained (> 0.9) and mean value thresholds were observed at 1.07 and 1.03, respectively. For K2/PSR in the reduced area, AUC was also superior to 0.9.

CONCLUSIONS: The implementation of a dynamic T2* perfusion sequence provided reliable results using an objective whole-lesion ROI. Perfusion parameters as well as a new permeability indicator could efficiently discriminate high-grade from low-grade lesions in the pediatric population.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Dallery F, Bouzerar R, Michel D, et al. Perfusion magnetic resonance imaging in pediatric brain tumors. Neuroradiology. 2017. PMID: 28861622. doi:10.1007/s00234-017-1917-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。