使用二氧化碳和虚拟小肠镜的CT小肠灌肠造影检测小肠肿瘤:一项初步研究
这项前瞻性研究纳入17例疑似小肠肿瘤患者,评估以二氧化碳扩张小肠的虚拟小肠镜(VE)的可行性、耐受性和诊断性能,并与34例匹配的接受中性对比剂CT小肠灌肠造影(CTE)患者比较辐射剂量。VE耐受性优良16/17例(94%),辐射剂量低于CTE(533±282 vs 974±505 mGy·cm,p=0.002)。VE在12/17例患者中检出25枚>5 mm息肉,病灶分析敏感度和阳性预测值均为92.0%,节段分析敏感度和特异度分别为95.0%和87.0%。
要点
- VE耐受性优良16/17例(94%),辐射剂量低于CTE(533±282 vs 974±505 mGy·cm,p=0.002)。
- VE在12/17例患者中检出25枚>5 mm息肉,病灶分析敏感度和阳性预测值均为92.0%。
- VE节段分析敏感度和特异度分别为95.0%和87.0%,作者认为其诊断小肠肿瘤可行且耐受良好。
核心结论
- 初步研究表明,虚拟小肠镜(VE)是可行且耐受良好的技术,对小肠肿瘤诊断具有较高的敏感度和特异度。
研究设计与样本
- 前瞻性研究,纳入17例疑似小肠肿瘤患者行二氧化碳扩张的VE,并与34例按年龄、性别和体重2:1匹配的接受中性对比剂CT小肠灌肠造影(CTE)患者比较辐射剂量;VE性能以手术和/或小肠镜和/或随访作为参考标准进行评价。
关键影像表现/征象
- VE在12/17例患者中检出25枚>5 mm息肉。
诊断标准与关键数值
- 病灶分析:VE敏感度92.0%,阳性预测值92.0%。
- 节段分析:VE敏感度95.0%,特异度87.0%。
- 辐射剂量:VE 533±282 mGy·cm vs CTE 974±505 mGy·cm,VE较低(p=0.002)。
- 耐受性:优良16/17例(94%)。
局限性
- 原文标题注明为初步研究(preliminary study),结论中表述为「Our preliminary study suggests」。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of this prospective study was to evaluate the feasibility, tolerance and performance of virtual enteroscopy (VE) using carbon dioxide for small-bowel distension in patients with suspected small-bowel tumours (SBTs).
PATIENTS AND METHODS: After IRB approval, 17 patients with suspected SBTs were prospectively included. Radiation dose was compared to 34 matched patients (2 for 1) for age, gender and body weight, who had undergone CT-enteroclysis with neutral contrast (CTE). Performance of VE was evaluated through comparison with the current standard of reference, including surgery and/or enteroscopy and/or follow-up.
RESULTS: Tolerance was excellent in 16/17 patients (94%). The radiation dose was lower for VE than for CTE (533 ± 282 vs. 974 ± 505 mGy.cm; p = 0.002). With VE, a total of 25 polyps >5 mm in size were depicted in 12/17 patients. On a per-lesion analysis, sensitivity and positive predictive value of VE were 92.0% and 92.0%, respectively. On a per-segment analysis VE had a sensitivity and specificity of 95.0% and 87.0%, respectively.
CONCLUSION: Our preliminary study suggests that VE is a feasible and well-tolerated technique with high sensitivity and specificity for the diagnosis of SBT.
KEY POINTS: • Virtual enteroscopy is feasible and well tolerated. • Virtual enteroscopy appears to be accurate for detection of small-bowel tumours. • Sensitivity and PPV of virtual enteroscopy is 92.0% and 92.0%. • Radiation dose is lower with virtual enteroscopy compared to MDCT-enteroclysis.
引用
- Dohan A, Boudiaf M, Dray X, et al. Detection of small-bowel tumours with CT enteroclysis using carbon dioxide and virtual enteroscopy: A preliminary study. Eur Radiol. 2017. PMID: 28710577. doi:10.1007/s00330-017-4927-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。