碘摄取对对比增强CT成像中患者组织吸收辐射剂量的影响:对CT剂量学的意义
该研究回顾性分析120例平扫与增强CT检查中放射性敏感组织的CT值升高,并用含碘水溶液体模建立CT值升高与碘浓度的关系,将临床碘摄取量代入数学人体模型进行蒙特卡罗模拟。结果显示增强CT期间组织平均碘摄取范围为0.02–0.46% w/w,最大值为0.82% w/w;相同CT曝光下含碘组织吸收剂量高于不含碘组织,高碘摄取组织剂量增加超过100%。作者结论认为给予碘对比剂会显著增加组织从CT曝光中吸收的辐射剂量。
要点
- 增强CT期间组织碘摄取平均为0.02–0.46% w/w,最大记录值为0.82% w/w。
- 相同CT曝光下,含碘组织吸收剂量高于不含碘组织,高碘摄取组织剂量增加超过100%。
- CT剂量学评估增强CT时应考虑组织碘摄取。
核心结论
- 给予碘对比剂会显著增加组织从CT曝光中吸收的辐射剂量,CT剂量学评估增强CT时应考虑组织碘摄取。
研究设计与样本
- 回顾性分析120例同时包含平扫与增强CT的检查,测定数种放射性敏感组织的对比剂所致CT值升高;采用含不同碘浓度水溶液的体模获得CT值升高与碘浓度的关系曲线;将临床碘摄取量量化为相应浓度的碘水溶液并代入数学人体模型;以蒙特卡罗方法模拟标准120 kV CT曝光,分别推导平扫与碘对比增强CT成像的器官剂量。
关键影像表现/征象
- 增强CT成像期间所研究组织的平均碘摄取范围为0.02–0.46% w/w。
- 记录到的最大碘摄取值为0.82% w/w。
- 相同CT曝光下,含碘组织吸收的辐射剂量高于不含碘组织。
- 高碘摄取组织的剂量增加超过100%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the effect of iodine uptake on tissue/organ absorbed doses from CT exposure and its implications in CT dosimetry.
METHODS: The contrast-induced CT number increase of several radiosensitive tissues was retrospectively determined in 120 CT examinations involving both non-enhanced and contrast-enhanced CT imaging. CT images of a phantom containing aqueous solutions of varying iodine concentration were obtained. Plots of the CT number increase against iodine concentration were produced. The clinically occurring iodine tissue uptake was quantified by attributing recorded CT number increase to a certain concentration of aqueous iodine solution. Clinically occurring iodine uptake was represented in mathematical anthropomorphic phantoms. Standard 120 kV CT exposures were simulated using Monte Carlo methods and resulting organ doses were derived for non-enhanced and iodine contrast-enhanced CT imaging.
RESULTS: The mean iodine uptake range during contrast-enhanced CT imaging was found to be 0.02-0.46% w/w for the investigated tissues, while the maximum value recorded was 0.82% w/w. For the same CT exposure, iodinated tissues were found to receive higher radiation dose than non-iodinated tissues, with dose increase exceeding 100% for tissues with high iodine uptake.
CONCLUSIONS: Administration of iodinated contrast medium considerably increases radiation dose to tissues from CT exposure.
KEY-POINTS: • Radiation absorption ability of organs/tissues is considerably affected by iodine uptake • Iodinated organ/tissues may absorb up to 100 % higher radiation dose • Compared to non-enhanced, contrast-enhanced CT may deliver higher dose to patient tissues • CT dosimetry of contrast-enhanced CT imaging should encounter tissue iodine uptake.