锥形束CT技术参数与肝细胞癌栓塞治疗患者诊断效用的关系
研究纳入29例肝细胞癌栓塞治疗患者,比较5秒(248幅投影)与8秒(396幅投影)锥形束CT与多排CT在病灶检出、血管显示及图像质量上的一致性。两种锥形束CT方案诊断信息等效,但5秒方案辐射剂量显著更低。
要点
- 5秒与8秒锥形束CT在显示大于1厘米病灶数目及最大病灶直径上与多排CT无显著差异。
- 两种锥形束CT均比多排CT更常显示亚段分支血管。
- 5秒锥形束CT诊断信息与8秒方案等效,且剂量面积乘积和皮肤剂量显著更低。
核心结论
- 5秒锥形束CT与8秒锥形束CT获得的诊断信息等效,且辐射剂量更低,多排CT与两种锥形束CT方案的关系一致。
研究设计与样本
- 研究纳入29例在2010至2013年间因肝细胞癌接受栓塞治疗并在术前6周内行增强多排CT的患者,每位患者均行5秒(248幅投影)或8秒(396幅投影)锥形束CT;由一名对分组不知情的介入放射科医师独立阅片,以多排CT为解剖参考,比较各组内锥形束CT与多排CT的一致性。
诊断标准与关键数值
- 组内比较多排CT与锥形束CT,在识别大于1厘米肿瘤病灶数目及测量最大病灶大小上无显著差异。
- 多排CT图像质量优于两种锥形束CT组(p<0.01),但两种锥形束CT组均比多排CT更常显示亚段分支。
- 两种锥形束CT组的对比噪声比均高于多排CT(p<0.01)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To determine the effect of different numbers of projection images in C-arm cone-beam computed tomography (CBCT) on diagnostic content and image quality in patients undergoing angiographic embolotherapy for hepatocellular carcinoma (HCC).
MATERIALS AND METHODS: A total of 29 patients who underwent contrast-enhanced conventional multidetector CT (MDCT) within 6 weeks prior to CBCT acquired during embolotherapy for HCC between 2010 and 2013 were included in the study. CBCT was acquired in each patient using a 5-s (248 projection images) or 8-s (396 projection images) protocol. Anonymised images were reviewed independently by an interventional radiologist blinded to CBCT group. MDCT was used as a reference to the patient's anatomy, and performance of CBCT was compared to that of MDCT in each group. The level of concordance between CBCT and MDCT within each group was assessed for the following variables: number of foci >1 cm, largest tumour diameter, highest order branching vessel identified, image quality, diagnostic quality, signal-to-noise ratio, and contrast-to-noise ratio (CNR). CBCT radiation dose was recorded.
RESULTS: There was no significant difference between MDCT and CBCT within each group in the number of tumour foci >1 cm identified or size of the largest focus measured. MDCT had superior image quality compared to both CBCT groups (p<0.01), but CBCT demonstrated subsegmental branches more often in each group than MDCT. Both CBCT groups demonstrated higher CNR than MDCT (p<0.01). The dose-area product (3675±1295 versus 6598±1252 μGy·m2; p<0.001) and skin dose (119±41 versus 212±38 mGy; p<0.001) were significantly lower with 5-s CBCT than with 8-s CBCT.
CONCLUSION: The relationship between MDCT and CBCT in both groups was consistent. The information obtained with 5-s CBCT was equivalent to that obtained with 8-s CBCT but with a lower radiation dose.
引用
- Gutierrez D, Gurajala RK, Kapoor B, et al. Relationship between cone-beam CT technique and diagnostic usefulness in patients undergoing embolotherapy for hepatocellular carcinoma. Clin Radiol. 2017. PMID: 28705329. doi:10.1016/j.crad.2017.06.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。