文献速递外周血管介入技术与安全CT

基于CT数据的三维打印内脏动脉瘤模型用于血管内栓塞模拟:尺寸与形状准确性评估

3D-Printed Visceral Aneurysm Models Based on CT Data for Simulations of Endovascular Embolization: Evaluation of Size and Shape Accuracy.
PubMed 文献 · AJR Am J Roentgenol · 2017-01-01

本研究基于CT血管成像数据制作15个真性内脏动脉瘤的三维打印中空模型,评估其尺寸与形状准确性。模型与患者数据的动脉瘤尺寸无统计学显著差异(p=0.56),整体动脉瘤及相关动脉的形状分析Dice系数为84.2%–95.8%(均值91.1%±4.1%)。作者结论认为模型尺寸和形状准确,可用于血管内治疗模拟并提供精确解剖信息。

要点

  • 基于CTA数据的三维打印中空内脏动脉瘤模型在尺寸上与患者数据无统计学显著差异(p=0.56)。
  • 整体动脉瘤及相关动脉形状分析的Dice系数为84.2%–95.8%(均值91.1%±4.1%)。
  • 作者认为该模型可用于血管内治疗模拟并提供精确解剖信息。

核心结论

  • 基于CTA数据制作的三维打印中空内脏动脉瘤模型尺寸和形状准确,可用于血管内治疗模拟并提供精确解剖信息。

研究设计与样本

  • 研究纳入2006年3月至2015年8月在本机构放射科接受血管内栓塞治疗的11例患者(8女3男,平均年龄61岁,范围53–72岁)的15个连续真性内脏动脉瘤,排除出血动脉瘤(n=3)及无薄层(<1 mm)栓塞前CT数据的动脉瘤(n=1)。

诊断标准与关键数值

  • 动脉瘤尺寸范围为138–18,691 mm³(直径6.1–35.7 mm),患者数据与三维打印模型间无统计学显著差异(p=0.56)。
  • 整体动脉瘤及相关动脉的形状分析显示高准确性,Dice系数指数值为84.2%–95.8%(均值±标准差,91.1%±4.1%)。

临床应用与阅片要点

  • 作者认为三维打印中空内脏动脉瘤模型可用于血管内治疗模拟并提供精确解剖信息。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The objective of this study is to verify the accuracy of 3D-printed hollow models of visceral aneurysms created from CT angiography (CTA) data, by evaluating the sizes and shapes of aneurysms and related arteries.

SUBJECTS AND METHODS: From March 2006 to August 2015, 19 true visceral aneurysms were embolized via interventional radiologic treatment provided by the radiology department at our institution; aneurysms with bleeding (n = 3) or without thin-slice (< 1 mm) preembolization CT data (n = 1) were excluded. A total of 15 consecutive true visceral aneurysms from 11 patients (eight women and three men; mean age, 61 years; range, 53-72 years) whose aneurysms were embolized via endovascular procedures were included in this study. Three-dimensional-printed hollow models of aneurysms and related arteries were fabricated from CTA data. The accuracies of the sizes and shapes of the 3D-printed hollow models were evaluated using the nonparametric Wilcoxon signed rank test and the Dice coefficient index.

RESULTS: Aneurysm sizes ranged from 138 to 18,691 mm3 (diameter, 6.1-35.7 mm), and no statistically significant difference was noted between patient data and 3D-printed models (p = 0.56). Shape analysis of whole aneurysms and related arteries indicated a high level of accuracy (Dice coefficient index value, 84.2-95.8%; mean [± SD], 91.1 ± 4.1%).

CONCLUSION: The sizes and shapes of 3D-printed hollow visceral aneurysm models created from CTA data were accurate. These models can be used for simulations of endovascular treatment and precise anatomic information.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Shibata E, Takao H, Amemiya S, et al. 3D-Printed Visceral Aneurysm Models Based on CT Data for Simulations of Endovascular Embolization: Evaluation of Size and Shape Accuracy. AJR Am J Roentgenol. 2017. PMID: 28731812. doi:10.2214/AJR.16.17694

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。