文献速递骨肌儿科影像介入CT

儿童手足骨样骨瘤成功采用射频神经切断探针治疗

Osteoid osteoma of the hand and foot in children successfully treated with radiofrequency neurotomy probes.
PubMed 文献 · Skeletal Radiol · 2017-07-08

本文报道2例儿童手足骨样骨瘤,均使用22G、2.5 mm活性端消融探针在CT引导下行射频消融,较小的消融体积保护了邻近神经血管结构并有效消融瘤巢;作者据此推荐在神经血管邻近使消融困难的病例中应用该方法。

要点

  • 儿童手足骨样骨瘤因病灶小且邻近重要神经血管结构,RFA风险较高。
  • 采用22G、2.5 mm活性端消融探针可减小消融体积,保护邻近神经血管结构。
  • 作者基于2例成功病例推荐在神经血管邻近使消融困难的病例中应用此方法。

核心结论

  • 使用22G、2.5 mm活性端消融探针的RFA成功治疗2例儿童手足骨样骨瘤,较小的消融体积在有效消融瘤巢的同时保护了邻近神经血管结构。

研究设计与样本

  • 病例报告,2例儿童患者(1例手部骨样骨瘤,1例足部骨样骨瘤),在CT引导下使用22G、2.5 mm活性端消融探针行射频消融。

诊断标准与关键数值

  • 使用22G、2.5 mm活性端消融探针进行射频消融。

临床应用与阅片要点

  • 作者推荐在神经血管邻近使消融困难的病例中应用该方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Osteoid osteoma is a common benign tumor that is typically found in young adults and children, usually in the long bones of the lower extremity. Radiofrequency ablation (RFA) under computed tomography guidance is the standard of care for symptomatic osteoid osteomas. However, patients with osteoid osteoma of the hand or foot are often treated with open surgery because of the risk of injury to vascular and neural structures from RFA. This risk is more pronounced in pediatric patients because of the small lesion size and proximity of lesions to important neurovascular structures. Here, we present 2 pediatric patients, one with an osteoid osteoma in the hand and the other with an osteoid osteoma in the foot. In both patients, a 22-gauge, 2.5-mm active tip ablation probe was used. The smaller ablation volume achieved with this probe protected neighboring neurovascular structures while effectively ablating the osteoid osteoma nidus. Based on our success in these cases, we recommend the application of this method for cases in which neurovascular proximity to the osteoid osteoma lesion makes ablation challenging.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Kuyumcu G, Sundaram M, Schils JP, et al. Osteoid osteoma of the hand and foot in children successfully treated with radiofrequency neurotomy probes. Skeletal Radiol. 2017. PMID: 28689337. doi:10.1007/s00256-017-2702-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。