文献速递骨肌MR

腓骨头投影在全膝关节置换术前规划中作为放射学标志物的价值有限

The fibular head projection is of limited use as a radiographic landmark in preoperative planning of total knee arthroplasty.
PubMed 文献 · Skeletal Radiol · 2017-06-29

本研究纳入334个膝关节的MRI,模拟平行于手术相关轴线的投影,测量腓骨头与胫骨外侧皮质骨的距离。结果发现腓骨头位置存在超过60°的个体间散布,虽存在近似线性相关(投影面每倾斜1.9°对应距离变化1mm),但腓骨头位置变异大,限制了其作为X线投影质量指标的可靠性。

要点

  • 腓骨头与胫骨外侧皮质骨的距离在个体间散布超过60°,变异大。
  • 投影面每倾斜1.9°,腓骨头与胫骨皮质骨距离变化约1mm,呈近似线性相关。
  • 腓骨头位置个体间变异大,限制了仅凭其位置判断X线投影质量的可靠性。

核心结论

  • 腓骨头位置个体间变异大,限制了基于腓骨头位置判断放射学投影质量的结论。

研究设计与样本

  • 基于334个膝关节MRI的影像学研究,在平行于手术相关轴线的投影上模拟测量腓骨头与胫骨外侧皮质骨的距离。

诊断标准与关键数值

  • 垂直于Akagi线的投影:腓骨头中心位于胫骨皮质骨外侧平均4.8±2.9 mm。
  • 平行于胫骨最大内外侧轴的投影:腓骨头中心位于胫骨皮质骨外侧平均7.5±3.4 mm。
  • 平行于后髁轴的投影:腓骨头中心位于胫骨皮质骨外侧平均5.6±3.6 mm。
  • 平行于手术上髁轴的投影:腓骨头中心位于胫骨皮质骨外侧平均6.1±3.5 mm。
  • 投影面每倾斜1.9°对应腓骨头与胫骨皮质骨距离变化1 mm,个体间散布超过60°。

临床应用与阅片要点

  • 原文确认了正确前后位投影时腓骨头部分被胫骨重叠的经验法则。

局限性

  • 腓骨头位置存在相当大的个体间变异,限制了基于腓骨头位置判断放射学投影质量的结论。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: The projection of the fibular head is recommended as a quality indicator of a correct radiographic projection. However, this landmark has yet to be sufficiently validated.

METHODS: The MRIs of 334 knee joints were included. On the MRIs, the distance between the FH and lateral tibial cortical bone was simulated in projections parallel to surgically relevant axes. Then, the Pearson correlation coefficient between the distance of the FH to the lateral tibial cortical bone and the projection plane causing this was determined.

RESULTS: A projection of the knee joint perpendicular to Akagi's line projected the center of the fibular head on average 4.8 ± 2.9 mm laterally of the tibial cortical bone, parallel to the maximum mediolateral axis of the tibia 7.5 ± 3.4 mm, parallel to the posterior condylar axis 5.6 ± 3.6 mm and parallel to the surgical epicondylar axis 6.1 ± 3.5 mm laterally of the tibial cortical bone. An almost linear correlation was seen, with 1.9° tilting of the projection plane per mm change in distance between the fibular head and tibial cortical bone. At the same time, the interindividual scatter was over 60°.

CONCLUSIONS: The rule of thumb for a partial overlap of the fibular head by the tibia in the case of a correct antero-posterior projection plane was also confirmed. However, a considerable interindividual variability of the position of the FH was found, which limits a conclusion regarding the quality of the radiographic projection on the basis of the position of the fibular head.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Matziolis D, Meiser M, Sieber N, et al. The fibular head projection is of limited use as a radiographic landmark in preoperative planning of total knee arthroplasty. Skeletal Radiol. 2017. PMID: 28664261. doi:10.1007/s00256-017-2705-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。