术前磁共振关节造影上撕裂肩袖的纹理分析作为术后肌腱状态的预测指标
回顾性纳入50例因冈上肌腱全层撕裂行关节镜下肩袖修复术的患者,基于术前T2加权磁共振关节造影图像,采用灰度共生矩阵对撕裂冈上肌腱远端最高信号强度区进行纹理分析。术后1年随访时30例肌腱完整、20例再撕裂;再撕裂组熵、方差和对比度更高,角二阶矩和逆差矩更低。retraction size(OR=3.053)和熵(OR=17.095)为显著预测因子。
要点
- 再撕裂组术前T2加权MRA撕裂冈上肌腱远端熵和方差显著高于完整组,角二阶矩和逆差矩显著更低。
- 再撕裂组撕裂size和retraction size均显著大于完整组。
- 熵(OR=17.095)和retraction size(OR=3.053)是术后肌腱状态的显著预测因子。
核心结论
- 术前T2加权MRA上对撕裂冈上肌腱行GLCM纹理分析可能有助于预测肩袖修复术后肌腱状态。
研究设计与样本
- 回顾性研究,纳入50例因冈上肌腱全层撕裂行关节镜下肩袖修复术的患者,基于术前T2加权磁共振关节造影图像,由两名放射科医师独立测量撕裂冈上肌腱远端最高信号强度区GLCM纹理特征,以术后1年随访MRI所示肌腱完整或再撕裂为参考标准分组比较。
诊断标准与关键数值
- 再撕裂组(20例)熵高于完整组(30例),P<0.001和P=0.001(两名医师测量)。
- 再撕裂组(20例)方差高于完整组(30例),P=0.030和P=0.011。
- 再撕裂组(20例)对比度高于完整组(30例),P=0.033和P=0.012。
- 再撕裂组(20例)角二阶矩低于完整组(30例),P<0.001和P=0.002;逆差矩低于完整组,P=0.027和P=0.027。
- 再撕裂组(20例)撕裂size大于完整组(30例),P=0.001;retraction size大于完整组,P=0.002。
临床应用与阅片要点
- 术前T2加权MRA上测量撕裂冈上肌腱远端最高信号强度区的GLCM纹理特征,可能有助于预测肩袖修复术后肌腱状态。
- retraction size(OR=3.053)和熵(OR=17.095)为术后肌腱状态的显著预测因子。
- 其他评估因素包括年龄、撕裂size(前后径)、retraction size(内外侧撕裂长度)、冈上肌腱和冈下肌腱脂肪变性分级及关节镜固定技术(单排或双排)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate texture data of the torn supraspinatus tendon (SST) on preoperative T2-weighted magnetic resonance arthrography (MRA) using the gray-level co-occurrence matrix (GLCM) for prediction of post-operative tendon state.
MATERIALS AND METHODS: Fifty patients who underwent arthroscopic rotator cuff repair for full-thickness tears of the SST were included in this retrospective study. Based on 1-year follow-up, magnetic resonance imaging showed that 30 patients had intact SSTs, and 20 had rotator cuff retears. Using GLCM, two radiologists measured independantly the highest signal intensity area of the distal end of the torn SST on preoperative T2-weighted MRA, which were compared between two groups.The relationships with other well-known prognostic factors, including age, tear size (anteroposterior dimension), retraction size (mediolateral tear length), grade of fatty degeneration of the SST and infraspinatus tendon, and arthroscopic fixation technique (single or double row), also were evaluated.
RESULTS: Of all the GLCM features, the retear group showed significantly higher entropy (p < 0.001 and p = 0.001), variance (p = 0.030 and 0.011), and contrast (p = 0.033 and 0.012), but lower angular second moment (p < 0.001 and p = 0.002) and inverse difference moment (p = 0.027 and 0.027), as well as larger tear size (p = 0.001) and retraction size (p = 0.002) than the intact group. Retraction size (odds ratio [OR] = 3.053) and entropy (OR = 17.095) were significant predictors.
CONCLUSION: Texture analysis of torn SSTs on preoperative T2-weighted MRA using the GLCM may be helpful to predict postoperative tendon state after rotator cuff repair.
引用
- Kang Y, Lee GY, Lee JW, et al. Texture Analysis of Torn Rotator Cuff on Preoperative Magnetic Resonance Arthrography as a Predictor of Postoperative Tendon Status. Korean J Radiol. 2017. PMID: 28670164. doi:10.3348/kjr.2017.18.4.691
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。