文献速递骨肌MR

常规临床膝关节MR报告:1.5 T与3.0 T对关节软骨评估的诊断性能比较

Routine clinical knee MR reports: comparison of diagnostic performance at 1.5 T and 3.0 T for assessment of the articular cartilage.
PubMed 文献 · Skeletal Radiol · 2017-07-17

该回顾性研究纳入297例患者共300个连续膝关节,比较1.5 T和3.0 T临床MRI报告对关节软骨的评估与关节镜的一致性。1.5 T与3.0 T的敏感度、特异度、分级一致百分比、分级在一级内百分比及加权kappa均无统计学显著差异。

要点

  • 1.5 T与3.0 T临床MRI报告对膝关节软骨评估的诊断性能无统计学显著差异。
  • 1.5 T的敏感度61.4%、特异度82.7%、分级一致62.2%、一级内77.5%。
  • 3.0 T的敏感度61.8%、特异度80.6%、分级一致59.5%、一级内75.6%。

核心结论

  • 1.5 T与3.0 T临床MRI报告对膝关节软骨评估的各项诊断性能参数均无统计学显著差异。

研究设计与样本

  • IRB批准的回顾性研究,纳入297例患者共300个连续膝关节,均有常规临床MRI和关节镜。
  • 1.5 T组165个膝关节,3.0 T组135个膝关节,比较MRI报告中的软骨描述与关节镜结果。
  • 对每个关节面计算敏感度、特异度、分级一致百分比、分级在一级内百分比及加权kappa。
  • 采用bootstrap获得标准误后以z检验进行显著性检验。

诊断标准与关键数值

  • 1.5 T:敏感度61.4%、特异度82.7%、分级一致百分比62.2%、分级在一级内百分比77.5%、加权kappa 0.56。
  • 3.0 T:敏感度61.8%、特异度80.6%、分级一致百分比59.5%、分级在一级内百分比75.6%、加权kappa 0.55。
  • 上述参数在1.5 T与3.0 T之间均无统计学显著差异。

局限性

  • 原文讨论了可能导致3.0 T MRI未显示诊断优势的因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Accurate assessment of knee articular cartilage is clinically important. Although 3.0 Tesla (T) MRI is reported to offer improved diagnostic performance, literature regarding the clinical impact of MRI field strength is lacking. The purpose of this study is to compare the diagnostic performance of clinical MRI reports for assessment of cartilage at 1.5 and 3.0 T in comparison to arthroscopy.

MATERIALS AND METHODS: This IRB-approved retrospective study consisted of 300 consecutive knees in 297 patients who had routine clinical MRI and arthroscopy. Descriptions of cartilage from MRI reports of 165 knees at 1.5 T and 135 at 3.0 T were compared with arthroscopy. The sensitivity, specificity, percent of articular surfaces graded concordantly, and percent of articular surfaces graded within one grade of the arthroscopic grading were calculated for each articular surface at 1.5 and 3.0 T. Agreement between MRI and arthroscopy was calculated with the weighted-kappa statistic. Significance testing was performed utilizing the z-test after bootstrapping to obtain the standard error.

RESULTS AND CONCLUSIONS: The sensitivity, specificity, percent of articular surfaces graded concordantly, and percent of articular surfaces graded within one grade were 61.4%, 82.7%, 62.2%, and 77.5% at 1.5 T and 61.8%, 80.6%, 59.5%, and 75.6% at 3.0 T, respectively. The weighted kappa statistic was 0.56 at 1.5 T and 0.55 at 3.0 T. There was no statistically significant difference in any of these parameters between 1.5 and 3.0 T. Factors potentially contributing to the lack of diagnostic advantage of 3.0 T MRI are discussed.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Mandell JC, Rhodes JA, Shah N, et al. Routine clinical knee MR reports: comparison of diagnostic performance at 1.5 T and 3.0 T for assessment of the articular cartilage. Skeletal Radiol. 2017. PMID: 28717928. doi:10.1007/s00256-017-2714-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。