文献速递骨肌MR

膝骨关节炎患者关节软骨钠MRI纵向研究:16个月随访的初步经验

Longitudinal study of sodium MRI of articular cartilage in patients with knee osteoarthritis: initial experience with 16-month follow-up.
PubMed 文献 · Eur Radiol · 2017-07-07

本研究对12例膝骨关节炎患者相隔约16个月行两次7T钠MRI扫描,分别采用无液体抑制的径向3D序列和绝热反转恢复(IR)液体抑制序列,测量髌骨、股胫内侧和外侧软骨区表观钠浓度(ASC)均值及标准差的变化及变化率;仅液体抑制序列显示ASC均值显著下降约70 mM(p=0.001)。作者认为7T绝热IR液体抑制定量钠MRI有潜力检测膝骨关节炎软骨ASC随时间下降。

要点

  • 7T钠MRI可检测关节软骨表观钠浓度(ASC)。
  • 仅绝热IR液体抑制序列显示两次扫描间ASC均值显著下降约70 mM(p=0.001)。
  • 该技术有潜力用于膝骨关节炎软骨退变的随访研究。

核心结论

  • 7T绝热IR液体抑制定量钠MRI有潜力检测膝骨关节炎患者关节软骨ASC随时间下降。

研究设计与样本

  • 纵向研究,12例膝骨关节炎患者相隔约16个月行两次7T钠MRI扫描,分别采用无液体抑制(径向3D)和绝热反转恢复(IR)液体抑制两种序列;在髌骨、股胫内侧和外侧软骨区测量ASC均值、标准差及其变化率(mM/day),采用配对Wilcoxon符号秩检验评估变化显著性。

关键影像表现/征象

  • 仅液体抑制序列采集的数据显示ASC均值、标准差及其变化率在两次扫描间有统计学差异。
  • 两次IR扫描间ASC均值显著下降约70 mM(p=0.001)。

诊断标准与关键数值

  • 表观钠浓度(ASC)以mM为单位测量,并计算其变化率(mM/day)。
  • 变化显著性采用配对Wilcoxon符号秩检验评估,p=0.001为两次IR扫描间ASC均值下降的显著性。

临床应用与阅片要点

  • 作者认为7T绝热IR液体抑制定量钠MRI有潜力用于膝骨关节炎软骨退变的随访研究。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the potential of sodium MRI to detect changes over time of apparent sodium concentration (ASC) in articular cartilage in patients with knee osteoarthritis (OA).

METHODS: The cartilage of 12 patients with knee OA were scanned twice over a period of approximately 16 months with two sodium MRI sequences at 7 T: without fluid suppression (radial 3D) and with fluid suppression by adiabatic inversion recovery (IR). Changes between baseline and follow-up of mean and standard deviation of ASC (in mM), and their rate of change (in mM/day), were measured in the patellar, femorotibial medial and lateral cartilage regions for each subject. A matched-pair Wilcoxon signed rank test was used to assess significance of the changes.

RESULTS: Changes in mean and in standard deviation of ASC, and in their respective rate of change over time, were only statistically different when data was acquired with the fluid-suppressed sequence. A significant decrease (p = 0.001) of approximately 70 mM in mean ASC was measured between the two IR scans.

CONCLUSION: Quantitative sodium MRI with fluid suppression by adiabatic IR at 7 T has the potential to detect a decrease of ASC over time in articular cartilage of patients with knee osteoarthritis.

KEY POINTS: • Sodium MRI can detect apparent sodium concentration (ASC) in cartilage • Longitudinal study: sodium MRI can detect changes in ASC over time • Potential for follow-up studies of cartilage degradation in knee osteoarthritis.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Madelin G, Xia D, Brown R, et al. Longitudinal study of sodium MRI of articular cartilage in patients with knee osteoarthritis: initial experience with 16-month follow-up. Eur Radiol. 2017. PMID: 28687914. doi:10.1007/s00330-017-4956-z