多探测器CT骨折评估中的辐射剂量降低
研究纳入398例肩、腕、骨盆及踝关节CT,低剂量CT管电流为标准剂量的一半。低剂量与标准剂量CT在各关节的图像噪声、主观评分及骨折诊断敏感度(96-100%)、特异度(95.2-100%)、准确率(97.9-100%)上均无显著差异。结论认为四肢低剂量CT可在不影响图像质量或诊断性能的情况下将辐射暴露降低约50%。
要点
- 四肢(肩、腕、骨盆、踝)低剂量CT管电流减半,骨折诊断敏感度96-100%、特异度95.2-100%、准确率97.9-100%。
- 低剂量与标准剂量CT各关节图像噪声及主观评分均无显著差异(p>0.05)。
- 低剂量CT较标准剂量CT辐射剂量降低约50%,不影响图像质量或骨折诊断性能。
核心结论
- 四肢骨折评估采用低剂量CT可将辐射暴露较标准剂量CT降低约50%,且不影响图像质量或诊断性能。
研究设计与样本
- 研究纳入398例患者CT扫描,包括肩103例、腕109例、骨盆98例、踝88例,女性191例、男性207例;低剂量CT采用与标准剂量相同的电压和参数,仅管电流降至标准剂量的一半;比较两者客观图像质量、主观图像质量评价及骨折诊断性能。
诊断标准与关键数值
- 标准剂量CT与低剂量CT诊断骨折的敏感度为96-100%、特异度为95.2-100%、准确率为97.9-100%,两者间差异无统计学意义(p值0.1336-1.000)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate whether multidetector CT with low-dose radiation (low-dose CT) of joints can be useful when evaluating fractures.
METHODS: Our study included CT scans of 398 patients, 103 shoulder cases, 109 wrist cases, 98 pelvis cases and 88 ankle cases. There were 191 females and 207 males. The low-dose CTs were performed using identical voltage and parameters with the exception of decreased (half of standard dose) tube current. Low-dose and standard-dose images were compared with regards to objective image quality, subjective evaluation of image quality and diagnostic performance for the fractures.
RESULTS: There was no significant difference of image noise between standard-dose CT and low-dose CT in every joint (p > 0.05). Each mean value of subjective score did not show significant difference according to the dosage of the CT scan. There were no statistically significant differences in the sensitivity (96-100%), specificity (95.2-100%) or accuracy (97.9-100%) between standard-dose CT and low-dose CT (p values, 0.1336-1.000).
CONCLUSION: The evaluation of extremities for fractures using low-dose CT can reduce radiation exposure by about 50% compared with standard-dose CT without affecting image quality or diagnostic performance. Advances in knowledge: Low-dose CT of the extremities (shoulder, pelvis, ankle and wrist) can reduce radiation dose by about 50% compared with standard-dose CT and does not significantly affect image quality or diagnostic performance in fracture detection.
引用
- Yi JW, Park HJ, Lee SY, et al. Radiation dose reduction in multidetector CT in fracture evaluation. Br J Radiol. 2017. PMID: 28707536. doi:10.1259/bjr.20170240
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。