文献速递乳腺乳腺X线

BI-RADS 3类比较:筛查召回后数字乳腺断层合成实施前后可能良性类别的评估

BI-RADS Category 3 Comparison: Probably Benign Category after Recall from Screening before and after Implementation of Digital Breast Tomosynthesis.
PubMed 文献 · Radiology · 2017-07-17

该回顾性研究比较了数字乳腺断层合成(DBT)与数字乳腺X线摄影(DM)筛查召回后诊断检查中BI-RADS 3类的使用率及2年结局。DBT组BI-RADS 3类使用率1.3%(206/15571)与DM组1.6%(168/10728)无显著差异(P=0.102),但建议短期随访的总体人数平均每1000名女性减少2.4例(95%CI:-0.5, 5.4)。DBT组召回病变类型分布显著改变,结构扭曲和肿块召回增加(P<0.001),不对称减少(P≤0.001),钙化无变化(P=0.977)。

要点

  • DBT筛查后BI-RADS 3类使用率1.3%(206/15571)与DM的1.6%(168/10728)无显著差异(P=0.102)。
  • DBT组建议短期随访人数平均每1000名女性减少2.4例(95%CI:-0.5, 5.4)。
  • DBT组结构扭曲和肿块召回增加(P<0.001),不对称召回减少(P≤0.001),钙化召回无变化(P=0.977)。

核心结论

  • DBT筛查未显著改变BI-RADS 3类使用率,但建议短期随访的总体人数平均每1000名女性减少2.4例(95%CI:-0.5, 5.4)。

研究设计与样本

  • 经机构审查委员会批准且符合HIPAA的回顾性审查,纳入10728例DM检查(2010年9月1日至2011年8月30日)和15571例筛查DBT检查(2011年10月1日至2013年2月28日)。

关键影像表现/征象

  • DBT组召回检查中结构扭曲和肿块召回增加(P<0.001),不对称召回减少(P≤0.001),钙化召回无变化(P=0.977)。
  • 诊断检查后给予BI-RADS 3类评估的病变类型未改变。

诊断标准与关键数值

  • BI-RADS 3类使用率:DM组168/10728(1.6%)vs DBT组206/15571(1.3%),P=0.102。
  • 建议短期随访人数平均每1000名女性减少2.4例(95%CI:-0.5, 5.4)。

临床应用与阅片要点

  • 筛查召回后诊断检查中,DBT与DM的BI-RADS 3类使用率无显著差异。
  • DBT筛查后召回病变类型分布改变,结构扭曲和肿块召回增加,不对称召回减少。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To evaluate Breast Imaging Reporting and Data System (BI-RADS) category 3 assessment at diagnostic examination after recall from screening in a large urban population after implementation of digital breast tomosynthesis (DBT) by focusing both on overall use and use stratified by recalled finding type and outcome at 2 years. Materials and Methods This was an intuitional review board-approved and HIPAA-compliant retrospective review of 10 728 digital mammography (DM) examinations from September 1, 2010, to August 30, 2011, and 15 571 screening DBT examinations from October 1, 2011, to February 28, 2013. The recall populations for DM and DBT were 1112 of 10 728 (10.4% of women screened) and 1366 of 15 571 (8.8% of women screened), respectively. Recall examinations were classified according to finding type: calcifications, asymmetry or focal asymmetry, mass, and architectural distortion. Differences between groups were compared by using the χ2 test. Results Although there was no significant change in the utilization rate of BI-RADS category 3 in those patients screened with DM compared with DBT (168 of 10 728, 1.6% for DM vs 206 of 15 571, 1.3% for DBT; P = .102), there was a mean overall reduction of 2.4 women per 1000 (95% confidence interval [CI]: -0.5, 5.4) recommended for short-term follow-up. Lesion types given a BI-RADS category 3 assessment after diagnostic work-up did not change. The distribution of recalled finding types significantly changed with DBT, with increased recall examinations for architectural distortion and mass (P < .001) and decreased recall examinations for asymmetries (P ≤ .001). There was no change in recall examinations for calcifications (P = .977). Conclusion Screening with DBT did not significantly change the utilization rate of BI-RADS category 3 classification; however, the overall number of patients recommended for short-interval follow-up decreased by a mean of 2.4 women per 1000 (95% CI: -0.5, 5.4). © RSNA, 2017 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. McDonald ES, McCarthy AM, Weinstein SP, et al. BI-RADS Category 3 Comparison: Probably Benign Category after Recall from Screening before and after Implementation of Digital Breast Tomosynthesis. Radiology. 2017. PMID: 28715278. doi:10.1148/radiol.2017162837

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。