使用实时虚拟超声成像(一种电磁追踪的乳腺超声与MRI协调系统)进行二次超声检查:一项初步研究
该回顾性初步研究纳入2011年7月至2015年5月间53例因俯卧位MRI检出乳腺病灶而接受二次超声的患者,共59个病灶。常规B模式超声识别20个(34%),其余39个中38个(97%)在补充仰卧位MRI上显示,33个(85%)通过实时虚拟超声成像(RVS)的二次超声检出,最终53个(90%)病灶经两种方式联合检出(p < 0.001)。作者认为,补充仰卧位MRI的RVS二次超声可能提高常规B模式隐匿性MRI检出乳腺病灶的超声及组织病理学检出率,但需进一步前瞻性研究。
要点
- 对俯卧位MRI检出但常规B模式超声隐匿的乳腺病灶,补充仰卧位MRI后使用RVS二次超声可检出其中85%(33/39)。
- 常规B模式二次超声仅检出34%(20/59)的MRI检出病灶,联合RVS后总检出率达90%(53/59)。
- RVS检出的33个病灶中24%(8/33)为恶性,76%(25/33)为良性。
核心结论
- 补充仰卧位MRI后使用RVS进行二次超声,可能提高常规B模式隐匿性MRI检出乳腺病灶的超声及组织病理学检出率,但需进一步前瞻性研究。
研究设计与样本
- 回顾性初步研究,2011年7月至2015年5月连续纳入53例患者,共59个俯卧位MRI检出病灶,均行常规B模式二次超声及补充仰卧位MRI后RVS二次超声,以US引导下RVS活检或切除活检为参考标准。
关键影像表现/征象
- 59个MRI检出病灶中,常规B模式二次超声识别20个(34%)。
- 39个常规B模式隐匿病灶中,38个(97%)在仰卧位MRI上显示,33个(85%)经RVS二次超声检出。
- RVS检出的33个病灶MRI形态类型为肿块16个、非肿块强化5个、焦点12个。
诊断标准与关键数值
- 常规B模式二次超声对MRI检出病灶的检出率为34%(20/59)。
- RVS二次超声对常规B模式隐匿病灶的检出率为85%(33/39)。
- 联合常规B模式与RVS的总检出率为90%(53/59),p < 0.001。
临床应用与阅片要点
- 对俯卧位MRI检出但常规B模式超声隐匿的乳腺病灶,可补充仰卧位MRI后使用RVS行二次超声。
- RVS检出病灶中24%(8/33)为恶性,需行US引导下RVS活检或切除活检确认。
- 剩余5个超声隐匿病灶可在RVS引导下于乳腺表面标记强化区后随访。
局限性
- 原文为回顾性研究。
- 原文为初步研究(pilot study)。
- 原文指出需进一步前瞻性研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Our aim was to retrospectively evaluate the utility of second-look ultrasound (US) using real-time virtual sonography (RVS) for detection of conventional B-mode (cB-mode) occult magnetic resonance imaging (MRI)-detected breast lesions. Between July 2011 and May 2015, 53 consecutive patients who underwent second-look US to identify lesions detected by prone MRI were enrolled in this study. Second-look US using RVS was performed for cB-mode occult MRI-detected breast lesions after an additional supine MRI. In the 53 patients, 59 lesions were initially detected by prone MRI, followed by second-look US. Of the 59 lesions, 20 (34%) were identified by second-look US using cB-mode. Of the 39 (66%) cB-mode occult lesions, 38 (97%) were detected in supine MRI and 33 (85%) were detected by second-look US using RVS. MRI morphology types of the 33 lesions were as follows: mass, 16; non-mass enhancement, 5; and focus, 12. US-guided biopsy under RVS or excisional biopsy demonstrated that of the 33 lesions, 8 (24%) were malignant and the remaining 25 (76%) were benign. A total of 53 (90%) MRI-detected lesions were sonographically identified using both cB-mode and RVS (p < 0.001). All five remaining US-occult lesions could be followed up under RVS after the enhancing area was marked on the breast surface using RVS. Although further prospective studies are required, the findings of our pilot study suggest that second-look US using RVS with additional supine MRI may improve the sonographic and histopathologic detection rate of cB-mode occult MRI-detected breast lesions.