文献速递乳腺乳腺X线

数字乳腺断层摄影的解读:与图像归档和通信系统(PACS)及专用工作站的初步比较研究

Interpretation of digital breast tomosynthesis: preliminary study on comparison with picture archiving and communication system (PACS) and dedicated workstation.
PubMed 文献 · Br J Radiol · 2017-07-14

本研究回顾性纳入97例用于筛查或诊断的数字乳腺断层摄影(DBT)图像,由三名独立放射科医师分别在专用工作站和PACS上结合数字乳腺X线摄影进行解读。工作站与PACS在癌检出AUC(0.839 vs 0.815,p=0.6375)和敏感度(81.8% vs 75.8%,p=0.2188)上无统计学显著差异,但工作站特异度显著更高(83.7% vs 76.9%,p=0.009);PACS平均解读时间显著更长(1.68 min/例 vs 1.35 min/例,p<0.0001)。

要点

  • 工作站与PACS的癌检出AUC和敏感度无统计学显著差异。
  • 工作站特异度83.7%显著高于PACS的76.9%(p=0.009)。
  • PACS平均解读时间1.68 min/例,显著长于工作站的1.35 min/例。

核心结论

  • 使用PACS解读DBT图像诊断性能与专用工作站相当,但解读时间更长。

研究设计与样本

  • 回顾性研究纳入97例用于筛查或诊断的DBT图像,由三名独立放射科医师分别在工作站和PACS上结合数字乳腺X线摄影解读,以组织病理学检查和随访数据为参考标准。

诊断标准与关键数值

  • 工作站与PACS的癌检出AUC分别为0.839和0.815(p=0.6375),敏感度分别为81.8%和75.8%(p=0.2188),特异度分别为83.7%和76.9%(p=0.009)。

临床应用与阅片要点

  • 当没有专用工作站时,使用PACS解读DBT图像是评估图像的一种替代选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the diagnostic accuracy and efficiency in the interpretation of digital breast tomosynthesis (DBT) images using a picture archiving and communication system (PACS) and a dedicated workstation.

METHODS: 97 DBT images obtained for screening or diagnostic purposes were stored in both a workstation and a PACS and evaluated in combination with digital mammography by three independent radiologists retrospectively. Breast Imaging-Reporting and Data System final assessments and likelihood of malignancy (%) were assigned and the interpretation time when using the workstation and PACS was recorded. Receiver operating characteristic curve analysis, sensitivities and specificities were compared with histopathological examination and follow-up data as a reference standard.

RESULTS: Area under the receiver operating characteristic curve values for cancer detection (0.839 vs 0.815, p = 0.6375) and sensitivity (81.8% vs 75.8%, p = 0.2188) showed no statistically significant differences between the workstation and PACS. However, specificity was significantly higher when analysing on the workstation than when using PACS (83.7% vs 76.9%, p = 0.009). When evaluating DBT images using PACS, only one case was deemed necessary to be reanalysed using the workstation. The mean time to interpret DBT images on PACS (1.68 min/case) was significantly longer than that to interpret on the workstation (1.35 min/case) (p < 0.0001).

CONCLUSION: Interpretation of DBT images using PACS showed comparable diagnostic performance to a dedicated workstation, even though it required a longer reading time. Advances in knowledge: Interpretation of DBT images using PACS is an alternative to evaluate the images when a dedicated workstation is not available.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Kim YS, Chang JM, Yi A, et al. Interpretation of digital breast tomosynthesis: preliminary study on comparison with picture archiving and communication system (PACS) and dedicated workstation. Br J Radiol. 2017. PMID: 28707529. doi:10.1259/bjr.20170182

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。