剪切波弹性成像对手术证实的乳腺乳头状病变:能否有效鉴别良恶性
研究纳入56个手术证实的乳腺乳头状病变(良性48个,恶性8个),评估剪切波弹性成像(SWE)鉴别良恶性的效能。B型超声的Az值最高为0.500,敏感度100%、特异度0%;平均弹性模量的Az值为0.721,高于B型超声(P<.01),最佳截断值44.3 kPa时敏感度75%、特异度75%。B型超声联合平均弹性模量截断值44.3 kPa后Az值提高至0.781,敏感度87.5%、特异度68.8%,假阳性活检率降至26.8%。结论认为在B型超声基础上加用SWE可能有助于鉴别乳腺乳头状病变的良恶性,并显著降低假阳性活检率。
要点
- B型超声鉴别乳腺乳头状病变良恶性的Az值仅0.500,特异度0%。
- 平均弹性模量Az值0.721,最佳截断值44.3 kPa,敏感度75%、特异度75%。
- B型超声联合SWE后假阳性活检率由85.7%降至26.8%。
核心结论
- 在B型超声基础上加用SWE可能有效鉴别乳腺乳头状病变的良恶性,并显著降低假阳性活检率。
研究设计与样本
- 回顾性分析56个手术证实的乳腺乳头状病变(良性48个[85.7%],恶性8个[14.3%]),采用B型超声和SWE检查,通过受试者工作特征曲线分析比较诊断效能。
诊断标准与关键数值
- B型超声Az值0.500(95%CI 0.363, 0.637),敏感度100%(8/8),特异度0%(0/48);平均弹性模量Az值0.721(95%CI 0.585, 0.833),最佳截断值44.3 kPa时敏感度75%、特异度75%;B型超声联合平均弹性模量截断值44.3 kPa后Az值0.781(95%CI 0.585, 0.833),敏感度87.5%、特异度68.8%。
临床应用与阅片要点
- 原文结论认为,在B型超声基础上加用SWE可能有助于鉴别乳腺乳头状病变的良恶性,并显著降低假阳性活检率。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the effectiveness of shear wave elastography (SWE) for differentiating benign from malignant breast papillary lesions METHODS: B-mode ultrasound (US) and SWE were available in 56 surgically confirmed papillary lesions (48 [85.7%] benign and 8 [14.3%] malignant). The diagnostic performances of US, SWE parameters, and combined US with SWE parameters were calculated by receiver operating characteristic curve analysis and compared.
RESULTS: The highest area under the receiver operating characteristic curve (Az ) value for US was 0.500 (95% confidence interval [CI], 0.363, 0.637). The sensitivity was 100% (8 of 8), and the specificity was 0% (0 of 48). False-positive biopsy results were obtained in 48 (85.7%) of 56 lesions. The Az value for mean elasticity (0.721; 95% CI, 0.585, 0.833) was higher than that for B-mode US (P < .01) and the highest with the optimal cutoff value of 44.3 kPa (sensitivity, 75%; specificity, 75%). By adding the mean elasticity cutoff value of 44.3 kPa to B-mode US, the performance was increased (Az , 0.781; 95% CI, 0.585, 0.833) with sensitivity of 87.5% and specificity of 68.8%, and false-positive biopsy results were reduced to 26.8%.
CONCLUSIONS: The additional use of SWE to B-mode US may be effective for differentiating benign and malignant breast papillary lesions, with a significant decrease in the false-positive biopsy rate.
引用
- Choi HJ, Ko KH, Jung HK, et al. Shear Wave Elastography for Surgically Verified Breast Papillary Lesions: Is It Effective for Differentiation Between Benign and Malignant Lesions? J Ultrasound Med. 2017. PMID: 28708299. doi:10.1002/jum.14293
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。