文献速递乳腺US

剪切波弹性成像与B型超声联合诊断乳腺肿块的效能比较:是否受肿块大小影响

Comparing Performance of Combinations of Shear Wave Elastography and B-Mode Ultrasound in Diagnosing Breast Masses: Is It Influenced by Mass Size?
PubMed 文献 · Ultrasound Med Biol · 2017-06-30

这项前瞻性研究纳入315例连续患者的326个乳腺肿块,在活检前进行超声和剪切波弹性成像检查,按肿块大小(≤15 mm和>15 mm)分组确定剪切波弹性成像参数的最佳阈值。联合方案取得的受试者工作特征曲线下面积为0.943,敏感度95.00%,特异度81.18%,接近单独超声的诊断效能;使用亚组阈值与使用全组阈值的联合方案效能无显著差异,但较大肿块亚组的最佳阈值更高。

要点

  • 联合方案AUC为0.943,敏感度95.00%,特异度81.18%,接近单独超声。
  • 按肿块大小(≤15 mm和>15 mm)分组确定剪切波弹性成像最佳阈值。
  • 较大肿块亚组的最佳阈值高于较小肿块亚组。

核心结论

  • 剪切波弹性成像与B型超声联合方案的诊断效能接近单独超声,AUC为0.943,敏感度95.00%,特异度81.18%。
  • 使用亚组阈值与使用全组阈值的联合方案效能无显著差异,但较大肿块亚组的最佳阈值更高。
  • 原文指出需进一步研究以确定肿块大小是否影响剪切波弹性成像与超声联合方案的效能。

研究设计与样本

  • 前瞻性研究,纳入315例连续患者的326个乳腺肿块,活检前进行超声和剪切波弹性成像检查。
  • 按肿块大小分为≤15 mm和>15 mm两个亚组,采用受试者工作特征曲线确定各亚组剪切波弹性成像参数的最佳阈值。

诊断标准与关键数值

  • 联合方案诊断乳腺肿块良恶性的AUC为0.943,敏感度95.00%,特异度81.18%。
  • 按肿块大小(≤15 mm和>15 mm)分别确定剪切波弹性成像参数的最佳阈值,较大肿块亚组的最佳阈值更高。
  • 使用亚组阈值的联合方案与使用全组阈值的联合方案效能无显著差异。

局限性

  • 原文指出需进一步研究以确定肿块大小是否影响剪切波弹性成像与超声联合方案的效能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

We determined the diagnostic performance of combinations of shear wave elastography (SWE) and B-mode ultrasound (US) in differentiating malignant from benign breast masses, and we investigated whether performance is affected by mass size. In this prospective study of 315 consecutive patients with 326 breast masses, US and SWE were performed before biopsy. Masses were categorized into two subgroups on the basis of mass size (≤15 mm and >15 mm), and the optimal thresholds for the SWE parameters were determined for each subgroup using receiver operating characteristic curves. The combination proposed here achieved an area under the receiver operating characteristic curve of 0.943, 95.00% sensitivity and 81.18% specificity, which approximated the diagnostic performance of US alone. The performance of the combinations using the subgroups' thresholds did not differ significantly from those based on the entire study group's thresholds, but the optimal thresholds were higher in the subgroup of larger masses. Further research is needed to determine whether mass size affects the performance of combinations of SWE and US.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Cong R, Li J, Wang X, et al. Comparing Performance of Combinations of Shear Wave Elastography and B-Mode Ultrasound in Diagnosing Breast Masses: Is It Influenced by Mass Size? Ultrasound Med Biol. 2017. PMID: 28673478. doi:10.1016/j.ultrasmedbio.2017.04.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。