文献速递乳腺CT

美国放射学会BI-RADS乳腺X线摄影图谱用于专用乳腺CT病变报告与评估的可行性初探

Potential Use of American College of Radiology BI-RADS Mammography Atlas for Reporting and Assessing Lesions Detected on Dedicated Breast CT Imaging: Preliminary Study.
PubMed 文献 · Acad Radiol · 2017-07-17

本研究纳入4名乳腺影像专科放射科医师,对30例含标记病灶的专用乳腺CT(DBCT)随机病例(共34个病灶)按BI-RADS乳腺X线摄影图谱第5版进行报告与评估。读者总体敏感度为0.969、特异度为0.529,报告主要征象的读者间一致性为高度一致(κ=0.70),乳腺密度和最终评估的一致性分别为中度(κ=0.53)和一般(κ=0.30)。作者认为将该图谱用于DBCT显示良好诊断性能和读者间一致性。

要点

  • DBCT病灶按BI-RADS乳腺X线摄影图谱第5版报告,读者总体敏感度0.969、特异度0.529。
  • 报告主要征象的读者间一致性为高度一致(κ=0.70)。
  • 乳腺密度和最终评估的读者间一致性分别为中度(κ=0.53)和一般(κ=0.30)。

核心结论

  • 将BI-RADS乳腺X线摄影图谱第5版用于DBCT病变报告与评估,显示读者诊断性能高且读者间一致性良好。

研究设计与样本

  • 经机构审查委员会批准、符合健康保险流通与责任法案的初步研究,纳入4名接受乳腺影像培训的放射科医师,对30例含标记病灶的随机DBCT病例(34个病灶)进行盲法独立阅片,参考标准为乳腺X线摄影和组织病理学结果,采用广义估计方程和Fleiss kappa统计量分析。

诊断标准与关键数值

  • 按BI-RADS乳腺X线摄影图谱第5版对每个标记DBCT病灶报告主要征象、特征、乳腺密度和最终评估;读者总体敏感度0.969、特异度0.529,不同病灶类型间敏感度和特异度无显著差异;报告主要征象总体一致性κ=0.70(高度一致),乳腺密度κ=0.53(中度一致),最终评估κ=0.30(一般一致)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Dedicated breast computed tomography (DBCT) is an emerging and promising modality for breast lesions. The objective of this study was to evaluate the potential use of applying the BI-RADS Mammography Atlas 5th Edition for reporting and assessing breast lesions on DBCT. Currently, no atlas exists for DBCT.

MATERIALS AND METHODS: Four radiologists trained in breast imaging were recruited in this institutional review board-approved, Health Insurance Portability and Accountability Act-compliant study. The enrolled radiologists, who were blinded to mammographic and histopathologic findings, individually reviewed 30 randomized DBCT cases that contained marked lesions. Thirty-four lesions were included in this study: 24 (70.6%) masses, 7 (20.6%) calcifications, and 3 (8.8%) architectural distortions. Eight (23.5%) lesions were malignant and 26 (76.5%) were benign. The reader was asked to specify according to the BI-RADS Mammography Atlas for each marked DBCT lesion: primary findings, features, breast density, and final assessment. We calculated readers' diagnostic performances for differentiating between benign and malignant lesions and interobserver variability for reporting and assessing lesions using a generalized estimating equation and the Fleiss kappa (κ) statistic.

RESULTS: The estimated overall sensitivity of the readers was 0.969, and the specificity was 0.529. There were no significant differences in the sensitivity and the specificity between lesion types. For reporting the presence of a primary finding, the overall substantial agreement (κ = 0.70) was seen. In assigning the breast density and the final assessment, the overall agreement was moderate (κ = 0.53) and fair (κ = 0.30).

CONCLUSION: The use of the BI-RADS Mammography Atlas 5th Edition for DBCT showed high performance and good agreement among readers.

来源:Acad Radiol,查看原文。版权归原作者所有。