文献速递妇产影像技术与安全US

使用平板平台和手机传输技术培训农村地区助产士完成基础产科床旁超声检查——一项WFUMB COE项目

Training Midwives to Perform Basic Obstetric Point-of-Care Ultrasound in Rural Areas Using a Tablet Platform and Mobile Phone Transmission Technology-A WFUMB COE Project.
PubMed 文献 · Ultrasound Med Biol · 2017-07-14

本研究评估助产士在无超声经验条件下使用平板超声扫描仪完成产科床旁超声、生成初步报告并经手机无损传输至放射科医生审核的流程。助产士报告与验证报告相关性极好,报告准确率99.63%,整体流转时间由35分钟降至25分钟,手机传输无故障且图像质量无下降。

要点

  • 助产士生成的初步报告与放射科医生验证报告相关性极好,报告准确率99.63%。
  • 手机无损传输图像无故障、无图像质量下降,整体流转时间由35分钟缩短至25分钟。
  • 仅发现1份助产士报告存在差异;20例高危患者中扫描结果与实际结局有2处差异。

核心结论

  • 培训助产士使用平板超声设备完成床旁超声并通过互联网将图像和报告传输给放射科医生审核是有价值的。
  • 聚焦高危患者的识别在偏远医疗机构中可能具有价值。

研究设计与样本

  • 本研究为WFUMB COE项目,评估助产士完成超声的准确性、平板超声扫描仪性能、助产士培训、远程放射学图像传输、放射科医生审核图像、助产士与放射科医生沟通、高危患者识别及教育与远程放射学模型改进等多个流程。
  • 助产士此前无超声经验,驻扎在首次提供床旁超声的农村地区。
  • 扫描后由助产士生成初步报告,连同全部图像以电子方式发送至主医院进行验证。
  • 使用独特软件通过调制解调器经手机发送无损图像,全部报告由本科室两名经验丰富的放射科医生验证并通过同一传输软件返回各中心。
  • 记录并监测传输时间、扫描质量、报告质量及其他参数。

关键影像表现/征象

  • 传输时间短,传输的图像质量极佳。
  • 手机传输无故障,图像质量无下降。

诊断标准与关键数值

  • 助产士完成的扫描报告准确率为99.63%。
  • 初步报告与验证报告之间相关性极好。
  • 助产士报告仅发现1处差异。
  • 扫描结果与实际结局在20例被识别为高危的患者中有2处差异。
  • 整体流转周转时间(从患者就诊到验证报告)最初为35分钟,后缩短至25分钟。

临床应用与阅片要点

  • 助产士扫描后生成初步报告并连同全部图像电子发送至主医院,由两名经验丰富的放射科医生验证后经同一软件返回各中心。
  • 手机无损传输图像质量无下降,可用于远程放射学审核。
  • 该流程聚焦高危患者识别,在偏远医疗机构中可能具有价值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Point-of-care ultrasound (POCUS) has become a topical subject and can be applied in a variety of ways with differing outcomes. The cost of all diagnostic procedures including obstetric ultrasound examinations is a major factor in the developing world and POCUS is only useful if it can be equated to good outcomes at a lower cost than a routine obstetric examination. The aim of this study was to assess a number of processes including accuracy of images and reports generated by midwives, performance of a tablet-sized ultrasound scanner, training of midwives to complete ultrasounds, teleradiology solution transmissions of images via internet, review of images by a radiologist, communication between midwife and radiologist, use of this technique to identify high-risk patients and improvement of the education and teleradiology model components. The midwives had no previous experience in ultrasound. They were stationed in rural locations where POCUS was available for the first time. After scanning the patients, an interim report was generated by the midwives and sent electronically together with all images to the main hospital for validation. Unique software was used to send lossless images by mobile phone using a modem. Transmission times were short and quality of images transmitted was excellent. All reports were validated by two experienced radiologists in our department and returned to the centers using the same transmission software. The transmission times, quality of scans, quality of reports and other parameters were recorded and monitored. Analysis showed excellent correlation between provisional and validated reports. Reporting accuracy of scans performed by the midwives was 99.63%. Overall flow turnaround time (from patient presentation to validated report) was initially 35 min but reduced to 25 min. The unique mobile phone transmission was faultless and there was no degradation of image quality. We found excellent correlation between final outcomes of the pregnancies and diagnoses on the basis of reports generated by the midwives. Only 1 discrepancy was found in the midwives' reports. Scan results versus actual outcomes revealed 2 discrepancies in the 20 patients identified as high risk. In conclusion, we found that it is valuable to train midwives in POCUS to use an ultrasound tablet device and transmit images and reports via the internet to radiologists for review of accuracy. This focus on the identification of high-risk patients can be valuable in a remote healthcare facility.