妊娠期复杂性超声附件肿块:盆腔MR成像对定性是否准确?
回顾性纳入31例孕妇共36个附件病变(27个良性、9个恶性),比较前瞻性超声与MR报告及两位放射科医师采用ADNEXMR-SCORE盲法判读的准确性。MR总体正确诊断32/36(88.9%),优于超声的27/36(75%);两位医师采用ADNEXMR-SCORE的敏感度均为100%,特异度分别为85.1%和77.7%,读者间kappa为0.914。
要点
- 妊娠期复杂性附件肿块行盆腔MR,采用ADNEXMR-SCORE定性,两位医师正确诊断分别为32/36和30/36。
- 两位医师MR敏感度均为100%,无恶性病变被判为良性;特异度R1为85.1%、R2为77.7%。
- MR总体正确诊断32/36(88.9%),高于前瞻性超声的27/36(75%)。
核心结论
- 盆腔MR对妊娠期偶然发现的复杂性附件肿块定性高度准确,两位读者采用ADNEXMR-SCORE的敏感度均为100%,无恶性病变被判为良性。
研究设计与样本
- 回顾性研究,纳入31例孕妇(中位年龄32岁,范围19-42岁;平均孕16周)共36个附件病变(平均大小103mm,范围20-290mm),其中27个良性、9个恶性。
关键影像表现/征象
- 病变平均大小103mm(范围20-290mm),36个病变中良性27个、恶性9个。
- 两位放射科医师盲法回顾性判读MR图像,依据ADNEXMR-SCORE将病变分为良性或恶性。
诊断标准与关键数值
- 前瞻性超声正确诊断27/36(75%,95%CI 58.9%-86.2%),前瞻性MR正确诊断32/36(88.9%,95%CI 74.6%-95.6%)。
- MR采用ADNEXMR-SCORE正确诊断:R1为32/36(88.9%,95%CI 74.6%-95.6%),R2为30/36(83.3%,95%CI 68.1%-92.1%)。
- MR采用ADNEXMR-SCORE的敏感度两位读者均为100%(95%CI 70.1%-1000%)。
- MR采用ADNEXMR-SCORE的特异度:R1为85.1%(95%CI 67.5%-94%),R2为77.7%(95%CI 59.2%-89.4%)。
- 两位读者间 reproducibility 近乎完美,kappa为0.914。
临床应用与阅片要点
- 作者结论认为MR对妊娠期复杂性附件肿块定性高度准确,可能有助于选择期待管理至分娩。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To retrospectively evaluate the accuracy of pelvic magnetic resonance (MR) imaging for the characterization of complex sonographic adnexal masses discovered in women during pregnancy.
STUDY DESIGN: The study population comprised 31 pregnant women (median age: 32 years (range: 19-42); mean gestation age of 16 weeks) referred to our institution for MR imaging for characterization of an adnexal mass discovered incidentally during routine ultrasound (US) for other indications. The population comprised of 31 women, with 36 adnexal lesions (mean size: 103mm [range: 20-290]), of which 27 were benign and 9 were malignant masses. Prospective US and MR reports were reviewed to determine the presence of a benign or malignant lesion. Two radiologists (R1 and R2) blinded to the final outcome, retrospectively evaluated the MR images using the criteria based on the ADNEXMR-SCORE and classified the lesion as benign or malignant. The reference standard was surgical pathology or at least a 1-year imaging follow-up.
RESULTS: Prospective US and MR imaging correctly identified the diagnosis in 27/36 (75%) (95% confidence interval (CI): 58.9%-86.2%) and in 32/36 (88.9%) (95% CI: 74.6%-95.6%) of lesions, respectively. MR imaging with ADNEXMR-SCORE allowed a correct diagnosis in 32/36 (88.9%) (95% CI: 74.6%-95.6%) of lesions for R1 and in 30/36 (83.3%) (95% CI: 68.1%-92.1%) of lesions for R2. The sensitivities and specificities of MR imaging using the MR ADNEXMR-SCORE were 100% (95% CI: 70.1%-1000%) for both readers and 85.1% (95% CI: 67.5%-94%) and 77.7% (95% CI: 59.2%-89.4%) for R1 and R2, respectively. No malignancy was classified as benign using MR criteria. The reproducibility between the two readers was almost perfect, with a kappa of 0.914.
CONCLUSION: MR imaging is highly accurate for the characterization of complex adnexal masses incidentally discovered during pregnancy.
CLINICAL RELEVANCE: MR imaging can accurately characterize adnexal masses in pregnancy and could be useful in opting for expectant management until delivery.
引用
- Thomassin-Naggara I, Fedida B, Sadowski E, et al. Complex US adnexal masses during pregnancy: Is pelvic MR imaging accurate for characterization? Eur J Radiol. 2017. PMID: 28668416. doi:10.1016/j.ejrad.2017.05.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。