胎儿生长受限妊娠中胎盘氧合改变的MR成像测量
这项病例对照研究于2010年10月至2015年10月纳入28例无并发症妊娠与23例胎儿生长受限(FGR)妊娠,行氧增强与血氧水平依赖(BOLD)MR成像定量胎盘纵向R1与横向R2*。FGR组基线R1与R2*均显著高于正常妊娠组,ΔR1与孕周呈显著负相关且FGR组较正常组低61.5%;以ΔPo2、基线R1与基线R2*区分FGR与正常妊娠的AUC为0.91。作者认为MR成像参数有潜力帮助识别与FGR相关的胎盘功能障碍,并可能有助于在小于胎龄儿中正确识别FGR。
要点
- FGR组胎盘基线R1为0.63 sec-1、R2*为26 sec-1,均显著高于正常妊娠组的0.59 sec-1与17 sec-1(P < .0001)。
- FGR组ΔR1总体较正常妊娠组低61.5%(P = .003)。
- 以ΔPo2、基线R1与基线R2*区分FGR与正常妊娠的AUC为0.91(95%CI:0.82,0.99)。
核心结论
- 正常妊娠与合并严重FGR的妊娠之间R1、R2*与ΔPo2存在显著差异;MR成像参数有潜力帮助识别与FGR相关的胎盘功能障碍,并可能有助于在小于胎龄儿中正确识别FGR。
研究设计与样本
- 病例对照研究,经当地研究伦理委员会批准,所有受试者均签署知情同意书;2010年10月至2015年10月共28例无并发症妊娠(个体化出生体重比[IBR] >第20百分位且分娩 >37周)与23例合并FGR的妊娠(IBR <第5百分位且多普勒超声异常)接受MR成像;数据前瞻性采集,组间差异回顾性解读(非配对t检验),并以孕周为协变量用logistic回归分析建立诊断模型。
诊断标准与关键数值
- 正常妊娠组基线R1为0.59 sec-1(95%CI:0.58 sec-1,0.60 sec-1)、R2*为17 sec-1(95%CI:14 sec-1,20 sec-1),FGR组基线R1为0.63 sec-1(95%CI:0.62 sec-1,0.65 sec-1)、R2*为26 sec-1(95%CI:22 sec-1,32 sec-1),两组差异P < .0001;合并队列中ΔR1与孕周呈显著负相关(P < .0001),FGR组ΔR1总体较正常妊娠组低61.5%(P = .003);以ΔPo2、基线R1与基线R2*区分FGR与正常妊娠的ROC曲线下面积为0.91(95%CI:0.82,0.99)。
临床应用与阅片要点
- 作者认为MR成像参数有潜力帮助识别与FGR相关的胎盘功能障碍,并可能有助于在小于胎龄儿中正确识别FGR。
局限性
- 作者指出需要更大规模的前瞻性研究来评估其超越超声所提供信息的增量获益。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To evaluate oxygen-enhanced and blood oxygen level-dependent (BOLD) magnetic resonance (MR) imaging parameters in normal pregnancies and those complicated by fetal growth restriction (FGR). Materials and Methods This case-control study was approved by the local research ethics committee. Informed consent was obtained from all subjects. From October 2010 to October 2015, 28 women with uncomplicated pregnancies (individualized birthweight ratio [IBR] >20th percentile and delivery >37 weeks) and 23 with pregnancies complicated by FGR (IBR <5th percentile and abnormal Doppler ultrasonography [US] studies) underwent MR imaging. Differences in placental longitudinal R1 (1/T1) and transverse R2* (1/T2*) were quantified, with subjects breathing either air or oxygen. The difference in R1 (ΔR1) after hyperoxia was converted to change in partial pressure of oxygen (ΔPo2). Data were acquired prospectively, with retrospective interpretation of group differences (unpaired t tests). Diagnostic models were developed by using logistic regression analysis with gestational age as a covariate. Results The mean baseline R1 and R2* for normal pregnancies (R1: 0.59 sec-1, 95% confidence interval [CI]: 0.58 sec-1, 0.60 sec-1; R2*: 17 sec-1, 95% CI: 14 sec-1, 20 sec-1) were significantly different from those of pregnancies complicated by FGR (R1: 0.63 sec-1, 95% CI: 0.62 sec-1, 0.65 sec-1; R2*: 26 sec-1, 95% CI: 22 sec-1, 32 sec-1) (P < .0001). The ΔR1 showed a significant negative association with gestational age (P < .0001) in the combined cohort, with the FGR group having a ΔR1 that was generally 61.5% lower than that in the normal pregnancy group (P = .003). The area under the receiver operating characteristic curve for the differentiation between pregnancy complicated by FGR and normal pregnancy by using ΔPo2, baseline R1, and baseline R2* was 0.91 (95% CI: 0.82, 0.99). Conclusion R1, R2*, and ΔPo2 were significantly different between normal pregnancies and those complicated by severe FGR. MR imaging parameters have the potential to help identify placental dysfunction associated with FGR and may have clinical utility in correctly identifying FGR among fetuses that are small for gestational age. A larger prospective study is needed to assess the incremental benefit beyond that offered by US. © RSNA, 2017.
引用
- Ingram E, Morris D, Naish J, et al. MR Imaging Measurements of Altered Placental Oxygenation in Pregnancies Complicated by Fetal Growth Restriction. Radiology. 2017. PMID: 28708473. doi:10.1148/radiol.2017162385
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。