文献速递妇产影像儿科影像US

远程超声:我们的准确度如何?

Teleultrasound: How Accurate Are We?
PubMed 文献 · J Ultrasound Med · 2017-06-29

本研究为经机构审查委员会批准的回顾性队列研究,评估远程超声产前诊断的敏感度与准确度,共纳入2368例解剖扫查。远程超声队列先天畸形患病率为5.66%,敏感度57.46%、特异度98.21%、准确度95.9%;82%患者1次完成解剖扫查。作者认为远程超声产前诊断的敏感度与准确度与已发表的现场超声文献相似,需进一步研究在同一人群内比较并验证这一可能节省成本的模式。

要点

  • 远程超声产前诊断先天畸形的敏感度为57.46%、特异度为98.21%、准确度为95.9%。
  • 远程超声队列先天畸形患病率为5.66%。
  • 82%患者1次完成解剖扫查,其余患者中分别有63%和61%需2次和3次。

核心结论

  • 远程超声用于产前诊断的敏感度与准确度与已发表的现场超声文献相似;需进一步研究在同一人群内比较敏感度与准确度,并进一步验证这一可能节省成本的模式。

研究设计与样本

  • 经机构审查委员会批准的回顾性队列研究,评估远程超声的敏感度与准确度;共评估2499例检查,纳入2368例;仅纳入解剖扫查,排除孕16周前、多胎妊娠及非解剖目的(如多普勒和羊水评估)的检查;产前诊断与产后诊断比较,后者来自覆盖全州、从孕20周前分娩至2岁婴儿的所有出生缺陷的强制出生缺陷监测项目。

诊断标准与关键数值

  • 远程超声队列先天畸形患病率5.66%;敏感度57.46%,特异度98.21%,准确度95.9%;82%患者1次完成解剖扫查,其余患者中63%需2次、61%需3次。

临床应用与阅片要点

  • 作者认为远程超声用于产前诊断的敏感度与准确度与已发表的现场超声文献相似;需进一步研究在同一人群内比较并进一步验证这一可能节省成本的模式。

局限性

  • 需进一步研究在同一人群内比较远程超声与现场超声的敏感度与准确度。
  • 需进一步验证这一可能节省成本的模式。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Ultrasound serves an important role in the prenatal diagnosis of fetal structural anomalies. Recently, there has been increased use of teleultrasound protocols. We aimed to evaluate the sensitivity and accuracy of teleultrasound.

METHODS: We conducted an Institutional Review Board-approved retrospective cohort study determining the sensitivity and accuracy of teleultrasound. In addition, we evaluated the number of ultrasound examinations required to complete an anatomic survey. Only ultrasound examinations performed for anatomic surveys were included. Studies were excluded if performed before 16 completed weeks' gestation, if they had multiple gestations, or for reasons other than anatomy (eg, Doppler studies and fluid assessment). Prenatal diagnoses were compared with postnatal diagnoses obtained from a robust mandatory birth defects surveillance program that records all birth defects in the entire state, from deliveries before 20 weeks' gestation through infants up to 2 years of age.

RESULTS: A total of 2499 studies were evaluated; 2368 were included. The teleultrasound cohort had a congenital anomaly prevalence of 5.66%. The sensitivity of teleultrasound was 57.46%; the specificity was 98.21%; and the accuracy was 95.9%. Anatomic surveys were completed after 1 visit in 82% of patients, whereas 63% and 61% of the remaining patients required 2 and 3 visits, respectively.

CONCLUSIONS: Teleultrasound for prenatal diagnosis has similar sensitivity and accuracy as the published literature for on-site ultrasound. Further studies are needed to compare the sensitivity and accuracy within the same population and further validate this potentially cost-saving modality.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Rabie NZ, Sandlin AT, Barber KA, et al. Teleultrasound: How Accurate Are We? J Ultrasound Med. 2017. PMID: 28660654. doi:10.1002/jum.14304

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。