丁溴东莨菪碱可显著减少前列腺多参数MRI的运动伪影并改善解剖结构显示
这项前瞻性研究纳入103例连续患者,在3.0T下比较注射40mg丁溴东莨菪碱前后高分辨率轴位T2加权TSE序列的图像质量。丁溴东莨菪碱在68%的患者中显著改善解剖评分(3.4±0.9升至4.4±0.7,p<0.001),在67%的患者中显著改善伪影评分,且效果与体重和前列腺体积无关,未报告副作用。
要点
- 丁溴东莨菪碱在68%患者中显著提高解剖结构评分,在67%患者中显著减少运动伪影。
- 丁溴东莨菪碱的效果与患者体重和前列腺体积无关。
- 注射丁溴东莨菪碱后非诊断性MRI比例降至<1%,未报告副作用。
核心结论
- 丁溴东莨菪碱可显著改善前列腺多参数MRI的图像质量并减少运动相关伪影,且效果不受体重或前列腺体积影响,未报告副作用。
研究设计与样本
- 前瞻性研究纳入103例连续患者(年龄65±10岁),在3.0T下先行无解痉剂的高分辨率轴位T2加权TSE序列,注射40mg丁溴东莨菪碱后重复该序列,随后行常规多参数MRI,由两名盲法阅片者按5分制评分。
关键影像表现/征象
- 丁溴东莨菪碱注射后解剖结构显示更清晰,两名阅片者平均解剖评分从3.4±0.9升至4.4±0.7(p<0.001)。
- 丁溴东莨菪碱注射后运动相关伪影减少,阅片者1平均伪影评分从3.2±1升至4.2±0.8(p<0.001),阅片者2从3.2±1升至4.1±0.8(p<0.001)。
诊断标准与关键数值
- 解剖结构和伪影均采用5分制评分,由两名盲法阅片者独立评估。
- 两名阅片者间一致性极好(k=0.95-0.98)。
临床应用与阅片要点
- 在前列腺多参数MRI中,注射40mg丁溴东莨菪碱后重复高分辨率轴位T2加权TSE序列可改善解剖细节显示并减少运动伪影。
- 丁溴东莨菪碱的效果与患者体重和前列腺体积无关,无需据此调整用药。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To prospectively evaluate the effect of hyoscine butylbromide (HBB) on visualisation of anatomical details and motion-related artefacts in mp-MRI of the prostate at 3.0 Tesla.
METHODS: One hundred and three consecutive patients (65 ± 10 years) were included in this trial, powered to demonstrate an improvement of image quality after HBB administration, assessed on a 5-point scale by two blinded readers. All patients received high-spatial resolution axial T2-weighted TSE sequences at 3.0 T without spasmolytic agent, repeated after application of 40 mg HBB and followed by routine mp-MRI. Secondary endpoints were (1) susceptibility to side effects, (2) dependence of spasmolytic effect on patients´ weight, and (3) prostate volume.
RESULTS: In 68% of patients, HBB significantly improved the anatomic score (mean 3.4 ± 0.9 before and 4.4 ± 0.7 after HBB for both readers, p = <0.001). In 67%, HBB significantly enhanced the artefact score (mean 3.2 ± 1 before and 4.2 ± 0.8 after HBB for reader 1, p = <0.001; 3.2 ± 1 and 4.1 ± 0.8 for reader 2, p = <0.001). Subgroup analysis revealed no statistically significant difference between patients with different bodyweight or prostate volume. Inter-reader agreement was excellent (k = 0.95-0.98).
CONCLUSIONS: Hyoscine butylbromide significantly improves image quality and reduces motion-related artefacts in mp-MRI of the prostate independent of bodyweight or prostate volume. No side effects were reported.
KEY POINTS: • Hyoscine butylbromide (HBB) improved image quality in over 2/3 of patients. • Severe artefacts were reduced after HBB in more than 20%. • The number of non-diagnostic MRI was reduced to <1% after HBB. • HBB effect was independent of bodyweight and prostate volume. • No side effects of HBB were reported in this study population.
引用
- Ullrich T, Quentin M, Schmaltz AK, et al. Hyoscine butylbromide significantly decreases motion artefacts and allows better delineation of anatomic structures in mp-MRI of the prostate. Eur Radiol. 2017. PMID: 28687912. doi:10.1007/s00330-017-4940-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。