超声剪切波弹性成像在糖尿病肾病评估中的应用
本研究纳入164例受试者(80例糖尿病肾病、84例无肾病或糖尿病对照),用虚拟触诊组织定量(VTQ)测量肾剪切波速度,发现糖尿病肾病患者肾剪切波速度低于正常对照,且eGFR<60 mL/min者低于eGFR>60 mL/min者,蛋白尿、糖尿病视网膜病变分期和糖化血红蛋白与VTQ值无相关性。
要点
- 糖尿病肾病患者右肾VTQ均值2.21±0.71 m/s、左肾2.13±0.72 m/s,均低于正常对照。
- eGFR<60 mL/min者肾剪切波速度2.09 m/s,低于eGFR>60 mL/min者的2.53 m/s(p<0.05)。
- 蛋白尿水平、糖尿病视网膜病变分期和糖化血红蛋白与VTQ值无相关性。
核心结论
- 糖尿病肾病且eGFR<60 mL/min患者的剪切波速度值显著低于eGFR>60 mL/min者(正常对照或DKD 1–2期糖尿病患者),且数值随eGFR下降而降低。
- 蛋白尿、糖尿病视网膜病变和糖化血红蛋白对VTQ无影响。
研究设计与样本
- 研究纳入164例受试者:80例糖尿病肾病患者和84例无肾脏疾病或糖尿病的对照。
- 每位受试者取侧卧位,每侧肾脏行5次有效VTQ测量,取中位数,结果以米/秒表示。
- 测量采用Virtual Touch组织定量(VTQ,Siemens Acuson S2000)行声辐射力脉冲弹性成像。
关键影像表现/征象
- 糖尿病肾病患者右肾VTQ中位数均值2.21±0.71 m/s、左肾2.13±0.72 m/s。
- 正常对照右肾VTQ中位数均值2.58±0.78 m/s(p=0.0017)、左肾2.46±0.81 m/s(p=0.006),高于糖尿病肾病患者。
诊断标准与关键数值
- eGFR>60 mL/min者(DKD 1–2期合并正常对照)肾剪切波速度2.53 m/s,高于eGFR<60 mL/min者的2.09 m/s(p<0.05)。
- 糖尿病肾病组右肾eGFR与VTQ水平呈显著相关(r=0.28,p=0.04)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
In previous studies of acoustic radiation force impulse (ARFI) elastography, using Virtual Touch tissue quantification (VTQ) (Siemens Acuson S2000), it was reported that the measurement of renal shear wave speed in patients with chronic kidney disease (CKD) is not influenced exclusively by renal fibrosis. The purpose of the present study was to analyze the role of VTQ in patients with diabetic kidney disease, considered the main cause of CKD. The study group included 164 patients: 80 patients with diabetic kidney disease (DKD) and 84 without renal disease or diabetes mellitus. In each subject in lateral decubitus, five valid VTQ measurements were performed in each kidney and a median value was calculated, the result being expressed in meters/second. The following means of the median values were obtained In DKD patients, the means of the median values were for VTQ right kidney, 2.21 ± 0.71 m/s, and for VTQ left kidney, 2.13 ± 0.72 m/s, whereas in the normal controls statistically significant higher values were obtained: 2.58 ± 0.78 m/s for VTQ right kidney (p = 0.0017) and 2.46 ± 0.81 m/s for VTQ left kidney (p = 0.006). Patients with an estimated glomerular filtration rate (eGFR) >60 mL/min (DKD stages 1 and 2 together with normal controls) had a significantly higher kidney shear wave speed compared with patients with an eGFR <60 mL/min (2.53 m/s vs. 2.09 m/s, p < 0.05). In the DKD group, there was a significant correlation between eGFR and VTQ levels for the right kidney (r = 0.28, p = 0.04). There was no correlation of VTQ values with proteinuria level, stage of diabetic retinopathy or glycated hemoglobin. Our study indicates that shear wave speed values in patients with diabetic kidney disease and eGFRs <60 mL/min are significantly lower compared with those of patients with eGFRs >60 mL/min (either normal controls or diabetic patients with DKD stages 1 and 2), and values decrease with the decrease in eGFR. However, proteinuria, diabetic retinopathy and glycated hemoglobin have no influence on VTQ.
引用
- Bob F, Grosu I, Sporea I, et al. Ultrasound-Based Shear Wave Elastography in the Assessment of Patients with Diabetic Kidney Disease. Ultrasound Med Biol. 2017. PMID: 28720285. doi:10.1016/j.ultrasmedbio.2017.04.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。