文献速递泌尿生殖PETCT

18F-FDG PET/CT对睾丸良恶性病变的鉴别与诊断

Differentiation and diagnosis of benign and malignant testicular lesions using 18F-FDG PET/CT.
PubMed 文献 · Eur J Radiol · 2017-05-26

回顾性分析53例经活检或手术病理证实的睾丸病变患者(恶性32例、良性21例)的18F-FDG PET/CT,良恶性病变的SUVmax及病变/本底比值差异均有统计学意义,恶性均高于良性;以SUVmax 3.75为最佳截断值,诊断敏感度90.6%、特异度80.9%、准确率86.8%。结论认为18F-FDG PET/CT能准确鉴别睾丸良恶性病变。

要点

  • 睾丸恶性病变SUVmax及病变/本底比值均高于良性病变(两者p=0.000)。
  • 鉴别良恶性最佳截断值为SUVmax 3.75。
  • 对应敏感度90.6%、特异度80.9%、准确率86.8%、阳性预测值87.9%、阴性预测值85.0%。

核心结论

  • 18F-FDG PET/CT能准确识别睾丸良恶性病变。

研究设计与样本

  • 回顾性分析53例经活检或手术病理证实的睾丸病变患者的18F-FDG PET/CT扫描,其中恶性肿瘤32例、良性病变21例,比较良恶性病变SUVmax及SUVmax病变/本底比值并计算诊断价值。

关键影像表现/征象

  • 恶性病变的SUVmax高于良性病变(Z=-4.295,p=0.000)。
  • 恶性病变的SUVmax病变/本底比值高于良性病变(Z=-5.219,p=0.000)。

诊断标准与关键数值

  • SUVmax 3.75为鉴别睾丸良恶性病变的最佳截断值。
  • 以SUVmax 3.75为截断值,诊断敏感度90.6%、特异度80.9%、准确率86.8%、阳性预测值87.9%、阴性预测值85.0%。

临床应用与阅片要点

  • 对睾丸病变可测量SUVmax及病变/本底比值,并以SUVmax 3.75作为良恶性鉴别的参考截断值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this study was to evaluate the differential diagnostic value of 18F-fluorodeoxy glucose positron emission tomography/computed tomography (18F-FDG PET/CT) for benign and malignant testicular lesions.

METHODS: The PET/CT scans of 53 patients with testicular lesions confirmed by biopsy or surgical pathology were retrospectively analyzed. There were 32 cases of malignant tumors and 21 cases of benign lesions. Differences in the maximum standardized uptake value (SUVmax) measurements and the SUVmax lesion/background ratios between benign and malignant lesions were analyzed. The diagnostic value of this PET/CT modality for the differential diagnosis of benign versus malignant testicular lesions was calculated.

RESULTS: The differences in the SUVmax measurements and the SUVmax lesion/background ratios between benign and malignant lesions were statistically significant (SUVmax: Z=-4.295, p=0.000; SUVmax lesion/background ratio: Z=-5.219, p=0.000); specifically, both of these indicators were higher in malignant lesions compared to benign lesions. An SUVmax of 3.75 was the optimal cutoff value to differentiate between benign and malignant testicular lesions. The diagnostic sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of this PET/CT modality in the differential diagnosis of benign versus malignant testicular lesions were 90.6%, 80.9%, 86.8%, 87.9%, and 85.0%, respectively.

CONCLUSIONS: 18F-FDG PET/CT can accurately identify benign and malignant testicular lesions.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Shao D, Gao Q, Tian XW, et al. Differentiation and diagnosis of benign and malignant testicular lesions using 18F-FDG PET/CT. Eur J Radiol. 2017. PMID: 28668404. doi:10.1016/j.ejrad.2017.05.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。