基于帧计数的胃衰减校正法用于儿童连续采集动态后位胃排空闪烁显像

Stomach frame-count-based attenuation correction of dynamic posterior view gastric emptying scintigraphy with continuous acquisition in children.
PubMed 文献 · Pediatr Radiol · 2017-07-06

研究开发了一种基于帧计数的后位衰减校正方法,用于儿童连续采集动态胃排空闪烁显像。回顾性分析122例同时采集后位和前位的检查,以后位衰减校正法获得的残留值与几何均值法无显著差异(P=0.813),而后位无衰减校正法与几何均值法差异显著(P<0.001)。作者认为该方法可替代几何均值法。

要点

  • 后位衰减校正法测得的胃排空残留值与几何均值法无显著差异(P=0.813)。
  • 后位无衰减校正法测得的残留值与几何均值法差异显著(P<0.001),趋于高估胃排空。
  • 作者提出基于帧计数的后位衰减校正可替代几何均值法用于1小时连续采集胃排空显像。

核心结论

  • 基于帧计数的后位衰减校正法获得的胃排空残留值与几何均值法无显著差异(P=0.813),可替代几何均值法。

研究设计与样本

  • 回顾性分析122例儿童胃排空闪烁显像研究,同时采集后位和前位,以后位衰减校正法与后位无衰减校正法分别与几何均值法(参考标准)比较。

诊断标准与关键数值

  • 后位衰减校正法残留值与几何均值法比较P=0.813;后位无衰减校正法残留值与几何均值法比较P<0.001。

临床应用与阅片要点

  • 在儿童连续采集动态胃排空闪烁显像中,可采用基于帧计数的后位衰减校正法替代几何均值法估算1小时胃排空残留分数。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: When performing dynamic gastric emptying scintigraphy with continuous acquisition in children, a single posterior view acquisition is preferred because it allows the young patient to more easily interact with a parent or technologist even though this method tends toward overestimating gastric emptying.

OBJECTIVES: The objective of our study was to develop a new attenuation correction (AC) method to improve the accuracy of the time activity curve and the measurement of residual gastric emptying from 1-h posterior images of gastric emptying scintigraphy with continuous acquisition.

MATERIALS AND METHODS: We developed a frame-count-based AC for gastric emptying scintigraphy from the posterior view (posterior AC method). We retrospectively reviewed 122 gastric emptying studies performed in children using conjugated posterior and anterior views, and evaluated the statistical differences between posterior only (without AC) and posterior AC using the geometric mean method as a reference standard.

RESULTS: The residual values obtained using posterior AC were not significantly different (P=0.813) compared to those using the geometric mean while the values using the posterior only were significantly different (P<0.001) from the geometric mean.

CONCLUSION: The proposed method can replace the geometric mean method to estimate gastric emptying residual fraction using patient-friendly posterior view without a significant difference in 1-h gastric emptying scintigraphy with continuous acquisition.

来源:Pediatr Radiol,查看原文。版权归原作者所有。