混合PET/MR系统全身肿瘤PET中飞行时间与点扩散函数技术的临床评估
本研究对14例患者54个直径≤30mm的小病灶行18F-FDG PET/MR,比较OSEM、OSEM+PSF、OSEM+TOF及OSEM+TOF+PSF四种重建算法。TOF与PSF联合使病灶SUVmean和SUVmax分别升高26.6%和30.0%,肝脏本底不受影响,作者认为可能改善小病灶可探测性。
要点
- TOF与PSF联合重建使小病灶SUVmean升高26.6%、SUVmax升高30.0%。
- 直径<10mm病灶SUVmean变化31.9%、SUVmax变化35.8%,高于10–30mm病灶。
- 肝脏本底SUV不受PSF或TOF影响,腹部病灶SUV高于胸部。
核心结论
- 在混合PET/MR图像中应用TOF和PSF显著提高了小病灶的SUV,可能改善小病灶可探测性。
研究设计与样本
- 对14例患者行18F-FDG PET/MR,评估54个直径≤30mm的小病灶,PET数据分别用OSEM、OSEM+PSF、OSEM+TOF和OSEM+TOF+PSF重建,行视觉评分与SUV定量分析,并按长轴直径和部位分组。
关键影像表现/征象
- OSEM+TOF+PSF的视觉评估与定量分析值最高,OSEM+TOF或PSF高于OSEM;TOF与PSF联合使SUVmean升高26.6%、SUVmax升高30.0%,肝脏SUV不受PSF或TOF影响。
诊断标准与关键数值
- 视觉评估采用3分制评分;病灶按长轴直径分组,直径<10mm病灶SUVmean变化31.9%、SUVmax变化35.8%,直径10–30mm病灶SUVmean变化24.5%、SUVmax变化27.6%。
临床应用与阅片要点
- 阅片时可注意TOF与PSF联合重建会提高小病灶SUV,直径<10mm病灶的SUV升高幅度大于10–30mm病灶,而肝脏本底SUV不受影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Hybrid positron emission tomography/magnetic resonance (PET/MR) imaging is a new multimodality imaging technology that can provide structural and functional information simultaneously. The aim of this study was to investigate the effects of the time-of-flight (TOF) and point-spread function (PSF) on small lesions observed in PET/MR images from clinical patient image sets.
MATERIALS AND METHODS: This study evaluated 54 small lesions in 14 patients who had undergone 18F-fluorodeoxyglucose (FDG) PET/MR. Lesions up to 30mm in diameter were included. The PET data were reconstructed with a baseline ordered-subsets expectation-maximization (OSEM) algorithm, OSEM+PSF, OSEM+TOF and OSEM+TOF+PSF. PET image quality and small lesions were visually evaluated and scored by a 3-point scale. A quantitative analysis was then performed using the mean and maximum standardized uptake value (SUV) of the small lesions (SUVmean and SUVmax). The lesions were divided into two groups according to the long-axis diameter and the location respectively and evaluated with each reconstruction algorithm. We also evaluated the background signal by analyzing the SUVliver.
RESULTS: OSEM+TOF+PSF provided the highest value and OSEM+TOF or PSF showed a higher value than OSEM for the visual assessment and quantitative analysis. The combination of TOF and PSF increased the SUVmean by 26.6% and the SUVmax by 30.0%. The SUVliverwas not influenced by PSF or TOF. For the OSEM+TOF+PSF model, the change in SUVmean and SUVmax for lesions <10mm in diameter was 31.9% and 35.8%, and 24.5% and 27.6% for lesions 10-30mm in diameter, respectively. The abdominal lesions obtained the higher SUV than those of chest on the images with TOF and/or PSF.
CONCLUSION: Application of TOF and PSF significantly increased the SUV of small lesions in hybrid PET/MR images, potentially improving small lesion detectability.
引用
- Shang K, Cui B, Ma J, et al. Clinical evaluation of whole-body oncologic PET with time-of-flight and point-spread function for the hybrid PET/MR system. Eur J Radiol. 2017. PMID: 28668434. doi:10.1016/j.ejrad.2017.05.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。