文献速递腹部技术与安全US

在临床实践中优化使用瞬时弹性成像与声辐射力脉冲成像对HIV/HCV合并感染患者进行肝纤维化分期

Optimal Use of Transient Elastography and Acoustic Radiation Force Impulse to Stage Liver Fibrosis in HIV/HCV-Coinfected Patients in Clinical Practice.
PubMed 文献 · J Ultrasound Med · 2017-07-17

研究纳入89例HIV/HCV合并感染患者,同日行瞬时弹性成像(TE)与声辐射力脉冲成像(ARFI),评估两种方法对肝纤维化F2、F3、F4分期的Kappa一致性,并基于与Kappa≥0.70相关的独立因素提出联合算法及成本效果分析。结果显示一致性中等,所提算法中ARFI作为首选技术具有成本效果。

要点

  • TE与ARFI对F2、F3、F4分期的Kappa一致性分别为0.55、0.59、0.69,属中等一致。
  • 超声脾脏大小正常与高病毒载量降低TE与ARFI一致的概率,超声左肝叶大小正常则提高一致概率。
  • 所提算法中74.16%患者肝纤维化评估充分,25.84%被错误分类;ARFI作为首选技术具成本效果。

核心结论

  • TE与ARFI对肝纤维化分期的一致性为中等;在所提算法中,ARFI作为研究人群肝纤维化分期的首选技术具有成本效果。

研究设计与样本

  • 共纳入89例HIV/HCV合并感染患者,同日行瞬时弹性成像(TE)与声辐射力脉冲成像(ARFI);用Kappa指数评估两技术一致性,基于多元回归分析中与Kappa≥0.70相关的独立因素提出联合ARFI与TE的算法,并进行成本效果分析;研究经机构审查委员会批准,所有患者签署知情同意。

诊断标准与关键数值

  • TE与ARFI对F2、F3、F4分期的Kappa一致性分别为0.55、0.59、0.69。

临床应用与阅片要点

  • 超声脾脏大小正常(OR 0.20;95%CI 0.05-0.91)与高病毒载量(OR 0.36;95%CI 0.17-0.77)降低TE与ARFI一致的概率,超声左肝叶大小正常(OR 3.32;95%CI 1.21-9.10)提高一致概率;所提算法中74.16%患者肝纤维化评估充分,25.84%被错误分类;TE相较ARFI使一致性每提高1%的增量成本效果比为€8.86;作者认为在研究人群中ARFI作为肝纤维化分期首选技术具有成本效果。

局限性

  • TE与ARFI的一致性为中等。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Liver fibrosis (LF) is crucial for the individualized management of patients with hepatitis C virus (HCV). We evaluated the concordance between two noninvasive methods for staging LF, transient elastography (TE) and acoustic radiation force impulse (ARFI), in patients coinfected with human immunodeficiency virus and HCV. We propose an algorithm for optimal use of both techniques in routine clinical practice.

METHODS: A total of 89 human immunodeficiency virus/HCV-coinfected patients underwent TE and ARFI on the same day. The kappa index was used to assess concordance between the techniques. An algorithm combining ARFI and TE was proposed based on the independent factors associated with a kappa index greater than or equal to 0.70, obtained from a multiple regression analysis. We performed a cost-effectiveness analysis. The study was approved by our institutional review board and all patients signed the informed consent.

RESULTS: Concordance between TE and ARFI for F2, F3, and F4 was 0.55, 0.59, and 0.69, respectively. Ultrasound normal spleen size (odds ratio [OR], 0.20; 95% confidence interval [CI], 0.05-0.91) and high viral load (OR, 0.36; 95% CI, 0.17-0.77) reduced the probability of agreement between TE and ARFI, whereas ultrasound normal left liver lobe size (OR, 3.32; 95% CI, 1.21-9.10) increased this probability. The algorithm revealed that LF was adequately assessed in 74.16%, with 25.84% of patients misclassified. The incremental cost-effectiveness ratio of TE compared with ARFI to increase concordance by 1% was €8.86.

CONCLUSIONS: Concordance between TE and ARFI was moderate. In the algorithm we proposed, ARFI was cost-effective as a first technique for the staging of LF in the study population.

来源:J Ultrasound Med,查看原文。版权归原作者所有。