文献速递腹部MR

注射流率对肝脏MRI动脉期图像劣化的影响:钆塞酸二钠与钆布醇的比较

Does injection flow rate have an impact on arterial phase image degradation in liver MRI? A comparison of gadoxetic acid versus gadobutrol.
PubMed 文献 · Clin Radiol · 2017-06-30

回顾性纳入200例连续肝脏MRI患者,分为三组:钆塞酸二钠(固定10 ml)1 ml/s组50例、2 ml/s组50例,钆布醇(0.1 mmol/kg)1 ml/s组100例。两位盲法独立阅片者用四级评分评估图像劣化。钆塞酸二钠2 ml/s组动脉期图像劣化发生率高于钆布醇1 ml/s组(阅片者2,p=0.032)。作者认为较慢注射流率有降低钆塞酸二钠肝脏MRI动脉期图像劣化发生率及严重程度的趋势。

要点

  • 钆塞酸二钠2 ml/s组动脉期图像劣化发生率16%(8/50),高于钆布醇1 ml/s组的5%(5/100,阅片者2,p=0.032)。
  • 钆塞酸二钠1 ml/s组动脉期图像劣化发生率为12%(6/50,两位阅片者一致)。
  • 钆塞酸二钠2 ml/s组严重动脉期图像劣化致图像不可诊断者占4%(2/50),1 ml/s组占2%(1/50)。

核心结论

  • 较慢注射流率有降低钆塞酸二钠肝脏MRI动脉期图像劣化发生率及严重程度的趋势。

研究设计与样本

  • 回顾性研究,纳入200例连续接受肝脏MRI的患者,符合HIPAA并获IRB批准,分为三组。

诊断标准与关键数值

  • 两位盲法独立阅片者采用四级评分评估增强前及增强后(动脉期、门静脉期、肝静脉期)图像劣化;采用Fisher精确检验比较三组动脉期图像劣化患者数。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate retrospectively the impact of injection flow rate on arterial phase image degradation in liver magnetic resonance imaging (MRI) with gadoxetic acid (Gd-EOB-DTPA) compared to gadobutrol.

MATERIALS AND METHODS: Two hundred consecutive patients who had undergone liver MRI were enrolled in this Health Insurance Portability and Accountability Act (HIPAA)-compliant institutional review board (IRB)-approved study and were divided into three groups. Group 1 (50 patients) and 2 (50 patients) had undergone MRI performed with gadoxetic acid (fixed 10 ml) at flow rate of 1 and 2 ml/s, respectively. Group 3 (100 patients) had undergone MRI performed with gadobutrol (0.1 mmol/kg) at 1 ml/s. Precontrast and post-contrast (arterial, portal venous, and hepatic venous phases) image degradation was assessed by two blinded independent readers using a four-point rating scale. The numbers of patients with arterial phase image degradation were compared using the Fisher exact test among the three groups.

RESULTS: The incidence of arterial phase image degradation was 12% (6/50) in group 1 and 16% (8/50) in group 2 for both readers, 6% (6/100) for reader 1 and 5% (5/100) for reader 2 in group 3. Group 2 had a higher incidence of arterial phase image degradation when compared with group 3 for reader 2 (p=0.032). Severe arterial phase image degradation, resulting in non-diagnostic image quality, occurred in 4% (2/50) of patients when performed with gadoxetic acid administration at 2 ml/s and 2% (1/50) at 1 ml/s.

CONCLUSION: A slower injection flow rate has a trend to reduce the incidence and severity of arterial phase image degradation during liver MRI with gadoxetic acid when compared to gadobutrol.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Cohen-Hallaleh V, Guo L, Hosseini-Nik H, et al. Does injection flow rate have an impact on arterial phase image degradation in liver MRI? A comparison of gadoxetic acid versus gadobutrol. Clin Radiol. 2017. PMID: 28673445. doi:10.1016/j.crad.2017.06.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。