文献速递腹部介入CTDSA

平板探测器CT原型金属伪影减少算法在接受经动脉肝放射性栓塞患者中的评估

Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation.
PubMed 文献 · Eur Radiol · 2017-07-14

本回顾性研究纳入29例接受经动脉放射性栓塞治疗的患者,评估锥形束CT-导管动脉造影中原型金属伪影减少(MAR)算法的效果。定量和定性分析显示,MAR算法可显著减少金属线圈和导管周围的条纹伪影,改善邻近肝实质和血管的可见性。

要点

  • MAR算法能显著降低金属线圈和导管周围的近场和远场条纹伪影(p<0.001)。
  • MAR校正后,邻近肝实质和血管的定性图像评分显著提高(p<0.003)。
  • 金属线圈所致的衰减不均匀性显著高于导管(p<0.001),校正后两者均显著下降(p<0.001)。

核心结论

  • 在接受锥形束CT-导管动脉造影的经动脉放射性栓塞患者中,原型MAR算法可改善金属线圈和导管伪影附近的图像质量。

研究设计与样本

  • 回顾性研究,纳入29例患者(平均年龄63.7±13.7岁,11例女性),其中16例有动脉金属线圈。使用锥形束CT-导管动脉造影(8秒扫描,200度旋转,397个投影),对校正和未校正图像进行定量和定性评估,比较近场(<1cm)和远场(>3cm)伪影源(金属线圈和导管)。

关键影像表现/征象

  • 金属线圈和导管伪影源在近场和远场的条纹伪影衰减变化在MAR校正后均显著降低(p<0.001)。
  • 未受影响器官的条纹伪影衰减在MAR校正前后保持稳定(所有p>0.05)。
  • 金属线圈的衰减值不均匀性显著高于导管(p<0.001),校正后两者均显著下降(p<0.001)。

诊断标准与关键数值

  • 定量评估指标为条纹伪影衰减变化,近场定义为距离伪影源<1cm,远场定义为>3cm。
  • 定性评估指标为肝实质和血管可见性评分,MAR校正后评分显著改善(所有p<0.003)。

临床应用与阅片要点

  • MAR算法可改善金属线圈和导管附近肝实质及血管的可见性,可能有助于图像判读。
  • 金属线圈产生的伪影程度似乎高于导管,MAR校正后两者伪影均减少。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses.

METHODS AND MATERIALS: Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (<1cm) and far-field (>3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared RESULTS: Quantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p<0.001), while remaining stable for unaffected organs (all p>0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (p<0.001) and decreased significantly for both after MAR (p<0.001). Qualitative image scores were significantly improved after MAR (all p<0.003) with by trend higher artefact degrees for metallic coils compared to catheters.

CONCLUSION: In patients undergoing CBCT-CA for transarterial RE, prototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts.

KEY POINTS: • Metal objects cause artefacts in cone-beam computed tomography (CBCT) imaging. • These artefacts can be corrected by metal artefact reduction (MAR) algorithms. • Corrected images show significantly better visibility of nearby hepatic vessels and tissue. • Better visibility may facilitate image interpretation, save time and radiation exposure.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Hamie QM, Kobe AR, Mietzsch L, et al. Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation. Eur Radiol. 2017. PMID: 28710583. doi:10.1007/s00330-017-4946-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。