文献速递腹部技术与安全MRPET

可变重聚焦翻转角单次激发快速自旋回波成像显示肝脏病灶:速度提升与病灶对比度增加

Variable refocusing flip angle single-shot fast spin echo imaging of liver lesions: increased speed and lesion contrast.
PubMed 文献 · Abdom Radiol (NY) · 2018-01-01

在43例已知胰腺神经内分泌肿瘤并接受全身PET/MRI分期患者中,比较可变重聚焦翻转角(vrf)单次激发快速自旋回波(SSFSE)与传统SSFSE序列的采集时间和临床图像质量。27例患者53个病灶分析显示,vrfSSFSE较SSFSE病灶对比噪声比更高(9.9±4.1 vs 6.7±4.1,p<0.001),平均重复时间更短(679±97 ms vs 1139±106 ms,p<0.0001),对应采集时间缩短1.7倍。结论认为vrfSSFSE可改善同期PET/MRI上肝脏转移灶的病灶对比度,并因SAR需求降低而显著缩短TR,使全肝可在单次20秒屏气内完成覆盖。

要点

  • vrfSSFSE较传统SSFSE病灶对比噪声比更高(9.9±4.1 vs 6.7±4.1,p<0.001)。
  • vrfSSFSE平均重复时间更短(679±97 ms vs 1139±106 ms,p<0.0001),采集时间缩短1.7倍。
  • vrfSSFSE可在单次20秒屏气内覆盖全肝,可能对PET/MRI扫描时间受限场景有临床意义。

核心结论

  • 与传统SSFSE相比,vrfSSFSE在同期PET/MRI上改善了肝脏转移灶的病灶对比度。
  • vrfSSFSE因SAR需求降低而显著缩短TR,使全肝可在单次20秒屏气内完成覆盖。
  • 作者认为这可能对PET/MRI中因需全身采集加床位特异性成像而扫描时间受限的场景有重要临床意义。

研究设计与样本

  • 本研究为在同期飞行时间3.0T PET/MRI上进行的序列比较研究,纳入43例已知胰腺神经内分泌肿瘤并接受68Ga-DOTA-TOC PET的患者。
  • 分析对象为有放射性核素摄取的≥1.5 cm肝脏病灶;共27例患者53个可评估病灶纳入分析。
  • 测量对比噪声比(CNR),并由四名盲法放射科医师评估整体图像质量;TR和CNR差异采用配对Student t检验(p<0.05为有统计学意义),读者间变异采用Fleiss kappa统计量评估。

诊断标准与关键数值

  • vrfSSFSE平均病灶CNR为9.9±4.1,SSFSE为6.7±4.1(p<0.001)。
  • vrfSSFSE平均TR为679±97 ms,SSFSE为1139±106 ms(p<0.0001),对应采集时间缩短1.7倍。
  • vrfSSFSE序列的肝脏病灶和胆总管图像整体质量在59%和67%的患者中分别被评分为优于或等同于SSFSE序列。

临床应用与阅片要点

  • 在PET/MRI肝脏病灶评估中,vrfSSFSE较传统SSFSE可提高病灶对比噪声比并缩短采集时间。
  • vrfSSFSE使全肝可在单次20秒屏气内完成覆盖,可能适用于扫描时间受限的PET/MRI全身采集场景。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate acquisition time and clinical image quality of a variable refocusing flip angle (vrf) single-shot fast spin echo (SSFSE) sequence in comparison with a conventional SSFSE sequence for imaging of liver lesions in patients undergoing whole-body PET/MRI for oncologic staging.

METHODS: A vrfSSFSE sequence was acquired in 43 patients with known pancreatic neuroendocrine tumors undergoing 68Ga-DOTA-TOC PET on a simultaneous time-of-flight 3.0T PET/MRI. Liver lesions ≥1.5 cm with radionucleotide uptake were analyzed. Contrast-to-noise ratios (CNRs) were measured, and four blinded radiologists assessed overall image quality. Differences in repetition time and CNR were assessed using a paired Student's t test with p < 0.05 considered statistically significant. Inter-reader variability was assessed with Fleiss' kappa statistic.

RESULTS: 53 eligible lesions in 27 patients were included for analysis. vrfSSFSE demonstrated higher mean lesion CNR compared to SSFSE (9.9 ± 4.1 vs. 6.7 ± 4.1, p < 0.001). Mean repetition time (TR) was 679 ± 97 ms for the vrfSSFSE sequence compared to 1139 ± 106 ms for SSFSE (p < 0.0001), corresponding to a 1.7-fold decrease in acquisition time. Overall quality of liver lesion and common bile duct images with the vrfSSFSE sequence was graded as superior than or equivalent to the SSFSE sequence for 59% and 67% of patients, respectively.

CONCLUSIONS: Compared to conventional SSFSE, vrfSSFSE resulted in improved lesion contrast on simultaneous PET/MRI in patients with liver metastases. Due to decreased SAR demands, vrfSSFSE significantly decreased TR, allowing coverage of the entire liver in a single twenty-second breath hold. This may have important clinical implications in the setting of PET/MRI, where scan time is limited by the necessity of whole-body image acquisition in addition to bed specific imaging.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Hicks RM, Loening AM, Ohliger MA, et al. Variable refocusing flip angle single-shot fast spin echo imaging of liver lesions: increased speed and lesion contrast. Abdom Radiol (NY). 2018. PMID: 28689221. doi:10.1007/s00261-017-1252-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。