文献速递腹部CTUS

肝脏影像报告与数据系统(LI-RADS)联合CT成像在肝硬化肝脏筛查超声检出的小结节(10-20 mm)分类中的诊断效能

Diagnostic efficacy of the Liver Imaging-Reporting and Data System (LI-RADS) with CT imaging in categorising small nodules (10-20 mm) detected in the cirrhotic liver at screening ultrasound.
PubMed 文献 · Clin Radiol · 2017-06-30

研究纳入55例肝硬化且超声筛查检出单发10-20 mm结节的患者,行肝脏CT并按LI-RADS分类,以细针穿刺活检为参考标准。结果显示,以高于LI-RADS 3类为确诊HCC阈值时,敏感度和特异度分别为72.7%和90%。作者认为CT联合LI-RADS对小肝结节诊断具有较强有效性,有助于提高CT报告准确性。

要点

  • 以高于LI-RADS 3类为HCC诊断阈值时,敏感度72.7%、特异度90%。
  • LI-RADS 5类结节中HCC占96%(22/23),3类中HCC占50%(7/14)。
  • LI-RADS联合CT对小肝结节诊断具有较强有效性,有助于提高CT报告准确性。

核心结论

  • CT联合LI-RADS对小肝结节诊断具有较强有效性,有助于提高CT报告准确性;联合LI-RADS 4类和5类用于确诊HCC可提高准确性和敏感度,且特异度或阳性预测值无明显受损。

研究设计与样本

  • 研究纳入55例肝硬化且超声监测检出单发直径10-20 mm结节的患者,均行肝脏CT和细针穿刺活检;所有CT图像按LI-RADS分为5类。

诊断标准与关键数值

  • 55个结节最终诊断:34个肝细胞癌、1个肝内胆管癌、1个肾上腺皮质癌转移、19个良性病变。

临床应用与阅片要点

  • 在超声监测检出结节的患者中,确诊HCC的最佳阈值为高于LI-RADS 3类,该阈值下敏感度72.7%、特异度90%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To estimate the diagnostic accuracy of the Liver Imaging-Reporting and Data System (LI-RADS) with computed tomography (CT) for diagnosing hepatic nodules (10-20 mm) detected in cirrhotic livers.

MATERIALS AND METHODS: Fifty-five patients with liver cirrhosis and a solitary nodule (10-20 mm in diameter) detected via ultrasound surveillance, underwent hepatic CT and fine-needle biopsy. All the CT images were analysed and the lesions were categorised into five categories according to the LI-RADS.

RESULTS: Final diagnoses of the 55 nodules were as follows: 34 hepatocellular carcinomas (HCCs), one intrahepatic cholangiocarcinomas, one adrenocortical carcinoma metastasis, and 19 benign lesions. None (0%) of four LI-RADS category 1 lesions, two (22%) of nine category 2 lesions, seven (50%) of 14 category 3 lesions, two (67%) of three category 4 lesions, 22 (96%) of 23 category 5 lesions and one (50%) of two lesions classified as other malignancies was HCC. One category 5 lesion was adrenocortical carcinoma metastasis and one of two lesions categorised as other malignancies was intrahepatic cholangiocarcinoma. In patients with nodules detected at surveillance ultrasound, the best threshold for confident HCC diagnosis was more than LI-RADS category 3. The use of this threshold produced a sensitivity and specificity of 72.7% and 90%, respectively. So combining LI-RADS 4 and 5 categories for confident HCC diagnosis would improve accuracy and sensitivity with no significant impairment of specificity or positive predictive value.

CONCLUSION: LIRADS with CT provides a strong validity for the diagnosis of small hepatic nodules, and is very useful to improve the accuracy of CT reports.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Abd Alkhalik Basha M, Abd El Aziz El Sammak D, El Sammak AA, et al. Diagnostic efficacy of the Liver Imaging-Reporting and Data System (LI-RADS) with CT imaging in categorising small nodules (10-20 mm) detected in the cirrhotic liver at screening ultrasound. Clin Radiol. 2017. PMID: 28673446. doi:10.1016/j.crad.2017.05.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。