文献速递腹部技术与安全US

使用对比增强超声成像和光声成像监测小鼠胆管炎模型中库普弗细胞吞噬活性受损及肝氧饱和度

Image Monitoring of the Impaired Phagocytic Activity of Kupffer Cells and Liver Oxygen Saturation in a Mouse Cholangitis Model Using Contrast-Enhanced Ultrasound Imaging and Photoacoustic Imaging.
PubMed 文献 · Ultrasound Med Biol · 2017-06-30

本研究通过胆总管结扎和左肝内胆管结扎建立小鼠胆管炎模型,采用Sonazoid对比增强超声和光声成像监测库普弗细胞吞噬功能及肝氧饱和度。结果显示结扎组库普弗相回声强度降低、肝氧饱和度下降、库普弗细胞分数升高,提示两种成像技术或可用于监测库普弗细胞吞噬活性受损及肝脏缺氧状态。

要点

  • Sonazoid对比增强超声的库普弗相回声强度降低可反映库普弗细胞吞噬活性受损。
  • 光声成像测得的肝氧饱和度下降提示胆管炎模型肝脏缺氧状态。
  • 库普弗细胞分数升高与库普弗细胞吞噬功能受损同时出现。

核心结论

  • 研究表明Sonazoid对比增强超声和光声成像可能是监测库普弗细胞吞噬活性受损及肝脏缺氧状态的有用工具。

研究设计与样本

  • 动物实验:小鼠胆管炎模型,胆总管结扎组n=20、左肝内胆管结扎组n=19,对照为非结扎组即左肝内胆管结扎后右叶测量组n=19和对照组n=14;采用对比增强超声和光声成像测量回声强度和肝氧饱和度,并评估库普弗细胞分数,于结扎后1、2、4周检测。

关键影像表现/征象

  • 结扎后2周,胆总管结扎组和左肝内胆管结扎组的库普弗相回声强度显著低于对照组和左肝内胆管结扎后右叶测量组(p < .01)。
  • 结扎后4周,胆总管结扎组和左肝内胆管结扎组的回声强度低于左肝内胆管结扎后右叶测量组(p < .01)。
  • 结扎后4周,胆总管结扎组和左肝内胆管结扎组的肝氧饱和度显著低于对照组和左肝内胆管结扎后右叶测量组(p < .01)。
  • 各时间点,胆总管结扎组和左肝内胆管结扎组的库普弗细胞分数均高于左肝内胆管结扎后右叶测量组和对照组(p < .01)。

临床应用与阅片要点

  • 作者认为Sonazoid对比增强超声和光声成像可能是监测库普弗细胞吞噬活性受损和肝脏缺氧状态的有用工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Bile duct ligation (BDL) can cause cholangitis, which is known to induce impaired Kupffer cell (KC) function and increased oxygen consumption in a mouse model. It is important to monitor changes in KC function and tissue oxygen saturation, both of which are critical factors in the progression of cholangitis. The purpose of this study is to investigate the impaired phagocytic activity of KC and liver oxygen saturation (sO2) in a mouse cholangitis model using contrast-enhanced ultrasound imaging (CEUS) and photoacoustic imaging (PAI). A mouse cholangitis model was created by ligation of the common bile duct (CBDL, n = 20), and the left intrahepatic bile duct (BDL-L, n = 19), both of which were compared with the non-ligation groups-right lobe measurement group after left intrahepatic bile duct ligation (BDL-R, n = 19) and the control group (n = 14). The echogenicity and sO2 were measured by CEUS and PAI and the KC fraction was assessed at 1, 2 and 4 wk after ligation. We found a significantly lower echogenicity of the Kupffer phase in the CBDL and BDL-L groups compared with that in the control and BDL-R groups at 2 wk (p < .01). The CBDL and BDL-L groups showed a lower echogenicity than that of the BDL-R group at 4 wk (p < .01). We found a significantly lower sO2 of the CBDL and BDL-L groups compared with that of the control and BDL-R groups at 4 wk (p < .01). The CBDL and BDL-L groups showed a higher KC fraction than that of the BDL-R and control groups at each time point (p < .01). In conclusion, our study suggests that the Sonazoid CEUS and PAI could be a useful tool for monitoring impaired KC phagocytic activity and the liver hypoxic state.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Lee S, Kim JH, Lee JH, et al. Image Monitoring of the Impaired Phagocytic Activity of Kupffer Cells and Liver Oxygen Saturation in a Mouse Cholangitis Model Using Contrast-Enhanced Ultrasound Imaging and Photoacoustic Imaging. Ultrasound Med Biol. 2017. PMID: 28673477. doi:10.1016/j.ultrasmedbio.2017.05.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。