文献速递腹部技术与安全MR

体素内不相干运动:基于机器学习的腹部器官组织类型无模型判定

Intravoxel Incoherent Motion: Model-Free Determination of Tissue Type in Abdominal Organs Using Machine Learning.
PubMed 文献 · Invest Radiol · 2017-01-01

在8名健康志愿者中,采用16个b值(0–1000 s/mm)的扩散数据,用k近邻机器学习算法以不同b值信号强度为特征区分肝、肾、脾、肌肉。在未参与算法优化的真实数据上,最佳准确度94.5%、κ=0.92(K=11);仅用6个最重要b值时平均准确度93.7%、κ=0.91。

要点

  • k近邻算法以多b值信号强度为特征,可在真实数据上准确区分肝、肾、脾、肌肉,最佳准确度94.5%。
  • 模型复杂度最优区间为K=11至13,K=11时κ=0.92,兼顾准确度与过拟合。
  • 主成分分析显示最重要b值依次为1000、970、750、20、620、40 s/mm,仅用前6个b值平均准确度仍达93.7%。

核心结论

  • 机器学习可利用体素内不相干运动信号衰减曲线作为特征,实现组织类型的无模型判定;该技术可能有助于腹部器官分割或区分健康与病理组织。

研究设计与样本

  • 在8名健康志愿者中,使用回波平面成像序列采集16个b值(范围0–1000 s/mm)的扩散数据集;采用k近邻技术,以不同b值信号强度为训练特征训练算法区分腹部器官(肝、肾、脾、肌肉),通过计算准确度和kappa系数评估性能,并用主成分分析确定最重要b值。

诊断标准与关键数值

  • 最佳准确度94.5%、κ=0.92(K=11,真实数据);仅用6个最重要b值时平均准确度93.7%、κ=0.91;最重要b值依次为b=1000、970、750、20、620、40 s/mm。

临床应用与阅片要点

  • 作者认为该技术可能有助于腹部器官分割或区分健康与病理组织。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: For diffusion data sets including low and high b-values, the intravoxel incoherent motion model is commonly applied to characterize tissue. The aim of the present study was to show that machine learning allows a model-free approach to determine tissue type without a priori assumptions on the underlying physiology.

MATERIALS AND METHODS: In 8 healthy volunteers, diffusion data sets were acquired using an echo-planar imaging sequence with 16 b-values in the range between 0 and 1000 s/mm. Using the k-nearest neighbors technique, the machine learning algorithm was trained to distinguish abdominal organs (liver, kidney, spleen, muscle) using the signal intensities at different b-values as training features. For systematic variation of model complexity (number of neighbors), performance was assessed by calculation of the accuracy and the kappa coefficient (κ). Most important b-values for tissue discrimination were determined by principal component analysis.

RESULTS: The optimal trade-off between model complexity and overfitting was found in the range between K = 11 to 13. On "real-world" data not previously applied to optimize the algorithm, the k-nearest neighbors algorithm was capable to accurately distinguish tissue types with best accuracy of 94.5% and κ = 0.92 reached for intermediate model complexity (K = 11). The principal component analysis showed that most important b-values are (with decreasing importance): b = 1000 s/mm, b = 970 s/mm, b = 750 s/mm, b = 20 s/mm, b = 620 s/mm, and b = 40 s/mm. Applying a reduced set of 6 most important b-values, still a similar accuracy was achieved on the real-world data set with an average accuracy of 93.7% and a κ coefficient of 0.91.

CONCLUSIONS: Machine learning allows for a model-free determination of tissue type using intra voxel incoherent motion signal decay curves as features. The technique may be useful for segmentation of abdominal organs or distinction between healthy and pathological tissues.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Ciritsis A, Rossi C, Wurnig MC, et al. Intravoxel Incoherent Motion: Model-Free Determination of Tissue Type in Abdominal Organs Using Machine Learning. Invest Radiol. 2017. PMID: 28742733. doi:10.1097/RLI.0000000000000400

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。