常规与低剂量水充盈CT诊断胃肿瘤与内镜比较的有用性
回顾性研究纳入40例经组织病理学确诊的胃肿瘤患者,均行内镜及常规或低剂量水充盈CT。水充盈CT诊断胃肿瘤类型的正确率为92.5%,与内镜的85%无显著差异;常规与低剂量水充盈CT的诊断准确率分别为95%和90%,无显著差异。作者认为水充盈CT可能是有价值无创诊断方法,适用于内镜禁忌或无法活检的患者。
要点
- 水充盈CT诊断胃肿瘤类型正确率92.5%,与内镜85%无显著差异。
- GIST诊断正确率内镜91.7%、水充盈CT 100%,无显著差异。
- 常规与低剂量水充盈CT诊断准确率分别为95%和90%,无显著差异。
核心结论
- 常规与低剂量水充盈CT可能是诊断胃肿瘤有价值的无创方法,适用于内镜禁忌或无法进行胃活检的患者。
研究设计与样本
- 回顾性研究,纳入40例经组织病理学确诊的胃肿瘤患者,均行内镜及常规或低剂量水充盈CT;水充盈CT图像由两名对內镜结果不知情的放射科医生共识判读,以组织病理学为参考标准。
诊断标准与关键数值
- 组织病理学证实胃癌28例(70%)、胃肠间质瘤(GIST)12例(30%);水充盈CT诊断肿瘤类型正确37例(92.5%),内镜准确率85%,无显著差异;GIST诊断正确率内镜91.7%、水充盈CT 100%,无显著差异;恶性肿瘤正确诊断率水充盈CT 89.29%,内镜82.14%(原文称内镜较低但无显著差异);常规与低剂量水充盈CT诊断准确率分别为95%和90%,无显著差异。
临床应用与阅片要点
- 作者认为常规与低剂量水充盈CT可能是诊断胃肿瘤有价值的无创方法,适用于有内镜禁忌或无法进行胃活检的患者。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of this retrospective study was to evaluate the usefulness of hydro-CT in the diagnosis of gastric tumors in comparison to endoscopy.
MATERIAL AND METHODS: The study involved 40 patients with a diagnosis of gastric tumor established by histopathology who underwent endoscopy and conventional or low-dose hydro-CT. Hydro-CT images were retrospectively analyzed based on the consensus of two radiologists who were blinded to the endoscopy findings. The diagnostic accuracy of hydro-CT and endoscopy for the diagnosis of gastric tumors was evaluated using the results of the histopathological examination as the reference standard.
RESULTS: Histopathology confirmed the presence of gastric cancer in 28 patients (70%), while gastrointestinal stromal tumors (GISTs) were recognized in the remaining 12 cases (30%). Correct diagnoses of the type of gastric tumor in hydro-CT were obtained in 37 patients (92.5%). This was not significantly different from the 85% accuracy of endoscopy. Further analysis showed that the correctness of GIST diagnosis in endoscopy and hydro-CT also did not differ significantly (91.7% and 100% respectively). The percentage of correctly diagnosed malignant lesions in hydro-CT was lower than for GISTs at 89.29%, while in endoscopy it was insignificantly lower (82.14%). The diagnostic accuracy of conventional and low-dose hydro-CT in the diagnosis of gastric tumors (95% and 90% respectively) was not significantly different.
CONCLUSIONS: Conventional and low-dose hydro-CT may be a valuable non-invasive diagnostic method in the diagnosis of gastric tumors for patients who have contraindications to endoscopy or who are unable to undergo gastric biopsy.