使用不同碘浓度(300与370 mg I/mL)碘普罗胺的腹盆腔CT图像质量定性与定量评估

Qualitative and Quantitative Assessment of Abdominal and Pelvic CT Image Quality Using Iopromide With Different Concentrations of Iodine (300 and 370 mg I/mL).
PubMed 文献 · AJR Am J Roentgenol · 2017-07-20

研究前瞻性纳入中国38家医院4506例接受腹盆腔MDCT并使用碘普罗胺的患者,比较300与370 mg I/mL两种碘浓度的图像质量。定性分级显示41.0%为优、54.5%为良、3.9%为合格、0.6%为差;是否使用生理盐水、16-MDCT与64-MDCT、300与370 mg I/mL之间未见差异。结论认为两种碘浓度均可提供可接受的图像质量,但CNR与SNR在不同情况下各浓度可能提供更优质量。

要点

  • 是否使用生理盐水及16-MDCT与64-MDCT之间图像质量未见差异。
  • CNR与SNR在不同碘浓度间因其他参数不同而存在差异。

核心结论

  • 碘普罗胺300与370 mg I/mL两种碘浓度均提供可接受的图像质量,但按CNR与SNR,不同情况下一种或另一种可能提供更优质量。

研究设计与样本

  • 前瞻性研究,纳入中国38家医院4506例接受腹盆腔MDCT并使用碘普罗胺的患者。
  • MDCT使用碘浓度300或370 mg I/mL的碘普罗胺,其中300 mg I/mL用于3042例(67.5%),370 mg I/mL用于1464例(32.2%)。
  • 图像质量定性分级为优、良、合格、差;客观指标为对比噪声比(CNR)与信噪比(SNR)。

诊断标准与关键数值

  • 图像质量分级:优1847例(41.0%)、良2454例(54.5%)、合格176例(3.9%)、差29例(0.6%)。
  • 是否使用生理盐水、16-MDCT与64-MDCT、300与370 mg I/mL碘普罗胺之间未见差异。
  • CNR与SNR在两种碘浓度间因其他参数不同而存在差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to analyze the quality of MDCT images obtained using iopromide with two different concentrations of iodine (300 and 370 mg I/mL) in daily clinical settings.

SUBJECTS AND METHODS: Patients from 38 hospitals in China undergoing abdominal or pelvic CT with iopromide were prospectively recruited. MDCT was performed using iopromide with an iodine concentration of 300 or 370 mg I/mL. CT quality image was graded as excellent, good, adequate, and poor. Objective indicators were the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). Outcomes were compared according to organ studied, tumor type (benign vs malignant), saline usage, and type of MDCT (16-MDCT vs 64-MDCT).

RESULTS: A total of 4506 patients (63.7% men) with a mean (± SD) age of 56.3 ± 14.1 years and mean body mass index (weight in kilograms divided by the square of height in meters) of 23.2 ± 3.3 were included. Iopromide with 300 mg I/mL was used for 3042 patients (67.5%), and 370 mg I/mL was used for 1464 patients (32.2%). A total of 1847 scans (41.0%) had excellent image quality, 2454 (54.5%) had good quality, 176 (3.9%) had adequate quality, and 29 (0.6%) had poor quality. No differences were noted between CT scans that did or did not use saline, 16-MDCT versus 64-MDCT scans, and 300 versus 370 mg I/mL iopromide. Variations in the CNR and SNR were noted between the two iodine concentrations with respect to other parameters examined.

CONCLUSION: Iopromide with both concentrations of iodine provided acceptable image quality, though according to CNR and SNR, one or the other may provide better quality in different situations.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Chen W, Li Z, Shuai T, et al. Qualitative and Quantitative Assessment of Abdominal and Pelvic CT Image Quality Using Iopromide With Different Concentrations of Iodine (300 and 370 mg I/mL). AJR Am J Roentgenol. 2017. PMID: 28726507. doi:10.2214/AJR.16.17302

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。