文献速递腹部外周血管泌尿生殖CT

肾血管CT:自适应统计迭代重建与基于模型的迭代重建的比较

Renovascular CT: comparison between adaptive statistical iterative reconstruction and model-based iterative reconstruction.
PubMed 文献 · Clin Radiol · 2017-06-30

回顾性纳入25例连续肾血管CT患者,同一原始投影数据分别用ASiR 40%、ASiR 100%和MBIR重建,比较背景噪声、CT衰减值、信噪比和图像质量。MBIR在第一、第二期背景噪声均显著低于ASiR 40%和100%(p<0.0001),肾血管及肾实质信噪比显著更高,肾动静脉显示和图像质量显著改善。

要点

  • MBIR重建的背景噪声显著低于ASiR 40%和100%(p<0.0001)。
  • MBIR的腹主动脉、肾动脉、肾皮质、肾静脉和肾髓质信噪比均显著高于ASiR(p<0.0001)。
  • MBIR的肾动脉、肾静脉显示及图像质量显著优于ASiR 40%和100%(p<0.0001-0.0016)。

核心结论

  • 肾血管CT采用MBIR重建较ASiR显著降低背景噪声,从而提高信噪比和图像质量。

研究设计与样本

  • 回顾性研究,纳入25例连续接受肾血管CT的患者,对同一原始投影数据分别行ASiR 40%、ASiR 100%和MBIR重建,比较三种重建技术的背景噪声、CT衰减值、信噪比和图像质量。

关键影像表现/征象

  • MBIR在第一期和第二期的平均背景噪声均显著低于ASiR 40%和100%(p<0.0001)。
  • 第一期腹主动脉、肾动脉和肾皮质以及第二期肾静脉和肾髓质的平均CT衰减值在三种重建技术间相当(p=0.051-1.00)。
  • MBIR的腹主动脉、肾动脉、肾皮质、肾静脉和肾髓质平均信噪比均显著高于ASiR 40%和100%(均p<0.0001)。
  • MBIR的肾动脉和肾静脉显示及图像质量较ASiR 40%和100%显著改善(p<0.0001-0.0016)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To compare contrast enhancement and image quality between renovascular computed tomography (CT) images with adaptive statistical iterative reconstruction (ASiR) and that with model-based iterative reconstruction (MBIR).

MATERIAL AND METHODS: This retrospective study was approved by the institutional review board and written informed consent was waived. Twenty-five consecutive patients who underwent renovascular CT were enrolled in this study. The same raw projection data were reconstructed using ASiR 40%, 100%, and MBIR. Background noise, CT attenuation, and signal-to-noise ratio (SNR) of the renal vessels and kidneys, and image quality were compared among the three reconstruction techniques.

RESULTS: Mean background noise was significantly lower with MBIR at the first and second phases than those with ASiR 40% and 100% (p<0.0001). Mean CT attenuation of the abdominal aorta, renal artery, and renal cortex obtained at the first phase and those of the renal vein and renal medulla at the second phase were comparable among the three techniques (p=0.051-1.00). Mean SNRs of the abdominal aorta, renal artery, renal cortex, renal vein, and renal medulla were significantly higher with MBIR than with ASiR 40% or 100% (both p<0.0001). The depiction of the renal artery and vein as well as image quality significantly improved with MBIR compared with those with ASiR 40% and 100% (p<0.0001-0.0016).

CONCLUSION: Reconstruction of renovascular CT images with MBIR significantly reduces background noise, leading to an improvement in SNR and image quality compared with that using ASiR.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Noda Y, Goshima S, Koyasu H, et al. Renovascular CT: comparison between adaptive statistical iterative reconstruction and model-based iterative reconstruction. Clin Radiol. 2017. PMID: 28673448. doi:10.1016/j.crad.2017.06.002