文献速递腹部MR

基于感兴趣区测量肝脏质子密度脂肪分数和R2*的标准化方法

Standardized Approach for ROI-Based Measurements of Proton Density Fat Fraction and R2* in the Liver.
PubMed 文献 · AJR Am J Roentgenol · 2017-07-13

本研究回顾性分析两个队列(53例腹部MRI受试者和37例疑似肝铁过载患者),评估不同感兴趣区采样策略测量化学位移编码MRI肝脏质子密度脂肪分数和R2*的可重复性与重现性。结果显示,在九个Couinaud段上取最大拟合感兴趣区并取平均值可获得最窄的一致性界限,但该方法耗时最长(每数据集平均149.7±8.6秒)。作者建议临床医生和研究者应尽可能使用多个大感兴趣区采样更多肝脏区域。

要点

  • 在九个Couinaud段上取最大拟合感兴趣区并平均,可获得最窄的PDFF和R2*一致性界限。
  • 该策略下PDFF的审查者间一致性界限为队列A ±0.8%、队列B ±1.7%,审查者内为队列A ±0.5%、队列B ±0.9%。
  • 该策略耗时最长,每数据集平均149.7±8.6秒。

核心结论

  • 为提高肝脏PDFF和R2*测量的重现性和可重复性,临床医生和研究者应使用多个大感兴趣区尽可能多地采样肝脏区域。

研究设计与样本

  • 回顾性分析两个队列的化学位移编码MRI数据;队列A为53例因腹部MRI转诊的患者及为CT与MRI对比研究招募的健康受试者,队列B为37例疑似肝铁过载患者;由三名审查者使用既往报道的感兴趣区采样策略测量肝脏PDFF和R2*,采用Bland-Altman分析评估审查者间和审查者内一致性。

诊断标准与关键数值

  • PDFF审查者间一致性平均一致性界限:队列A ±0.8%,队列B ±1.7%;审查者内一致性:队列A ±0.5%,队列B ±0.9%。
  • R2*审查者间一致性平均一致性界限:队列A ±3.0 s-1,队列B ±17.9 s-1;审查者内一致性:队列A ±2.6 s-1,队列B ±14.6 s-1。
  • 在九个Couinaud段上取最大拟合感兴趣区并平均,获得两个队列中PDFF和R2*测量最窄的一致性界限。

临床应用与阅片要点

  • 作者建议临床医生和研究者应使用多个大感兴趣区尽可能多地采样肝脏区域,以提高PDFF和R2*测量的重现性和可重复性;该策略耗时最长,每数据集平均149.7±8.6秒。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to evaluate the reproducibility (interreviewer agreement) and repeatability (intrareviewer agreement) of ROI sampling strategies to measure chemical shift-encoded (CSE) MRI-based liver proton density fat fraction (PDFF) and R2* (1 / T2*). A secondary purpose was to standardize ROI-based liver PDFF and R2* measurements by providing a compromise between measurement reproducibility and repeatability and time burden for image analysts.

MATERIALS AND METHODS: CSE data from two cohorts were retrospectively analyzed. Cohort A included 53 patients referred for abdominal MRI and healthy subjects recruited for a comparison study of CT and MRI. Cohort B included 37 patients with suspected liver iron overload. Three reviewers measured liver PDFF and R2* using previously reported ROI sampling strategies. Inter- and intrareviewer agreement of liver PDFF and R2* were evaluated using Bland-Altman analysis.

RESULTS: Averaging largest-fit ROIs over the nine Couinaud segments resulted in the narrowest limits of agreement (LOA) for liver PDFF and R2* measurements in both cohorts. For PDFF, interreviewer agreement had mean LOA of ± 0.8% for cohort A and ± 1.7% for cohort B. Intrareviewer agreement was ± 0.5% for cohort A and ± 0.9% for cohort B. For R2* interre-viewer agreement had mean LOA of ± 3.0 s-1 for cohort A and ± 17.9 s-1 for cohort B. Intrare-viewer agreement was ± 2.6 s-1 for cohort A and ± 14.6 s-1 for cohort B. This approach was the most time-burdensome, requiring a mean ± SD of 149.7 ± 8.6 s per dataset.

CONCLUSION: For improved reproducibility and repeatability of liver PDFF and R2* measurements, clinicians and researchers should sample as much area of the liver as possible using multiple large ROIs.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Campo CA, Hernando D, Schubert T, et al. Standardized Approach for ROI-Based Measurements of Proton Density Fat Fraction and R2* in the Liver. AJR Am J Roentgenol. 2017. PMID: 28705058. doi:10.2214/AJR.17.17812

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。